October 7, 2012
115-V 20-Amp 60-Hz Self-Timed Unit
47
REMOVE AND REPLACE TIMER
Do this FIRST
Make.certain.you.have.all.the.necessary.parts.and.fasteners.necessary.for.correct.installation..Parts.used.in.
this.process:.(1).AEC1219.Timer,.(4).AEC1809.Nylon.Spacers,.(2).AEC1808.Star.Lock.Washers,.(2).AEC1804.
S.S..Nuts,.(2).AEC1831.Machine.Screws,.(1).AEC1250.Gasket,.and.(1).AEC1245.Micro.Switch.Box.Cover.
REMOVE TIMER
1).Turn.off.the.main.electrical.power.to.the.unit.–.place.a.lockout.tag.on.the.circuit.breaker.panel.indicating.that.
....the.breaker.is.not.to.be.turned.on.except.by.authorized.personnel.and.disconnect.the.unit.before.doing.any.
....work.on.the.SUITMATE
®
.unit..Simply.turning.off.a.switch.is.NOT.enough.
2).Remove.SUITMATE
®
.unit.from.the.Wall.Mount.Bracket..See.instructions.beginning.on.Page.14..Place.the
....SUITMATE
®
.on.its.front.side.
3).Remove.the.Micro.Switch.Box.Cover.to.expose.the.Micro.Switch.and.Riser.Cable.lower.assembly.by.
....unscrewing.(2).screws..Place.the.screws.aside.for.reassembly.later.
4).Remove.the.(2).Nuts,.(2).Lock.Washers.and.(4).Spacers.to.access.the.Timer..Set.the.hardware.aside.for.
....reassembly.
5).Remove.the.Timer.from.the.mounting.studs.
REPLACE TIMER
1).Remove.the.wires,.one.at.a.time,.and.put.each.wire.in.the.matching.position.on.the.new.Timer.
2).Place.the.newly.wired.Timer.on.the.mounting.studs..Use.the.(4).Spacers.(2).Nuts,.and.(2).Lock.Washers.
....previously.removed.to.secure.the.new.Timer...
Note:
Do not over tighten the Nuts!
3).Replace.the.Micro.Switch.Box.Cover.and.secure.it.in.place.using.the.previously.removed.screws.
WARNING!
Make certain the foam seal on the Micro Switch Box Cover is not damaged so
that water cannot enter the Micro Switch Box.
4).Reinstall.the.SUITMATE
®
.unit.to.the.Wall.Mount.Bracket..See.instructions.beginning.on.Page.14.
5).Turn.on.the.main.electrical.power.to.the.unit.and.retest.to.assure.proper.operation..Refer.to.TESTING.
....AND.OPERATION.on.Page.7.
HOW TO BYPASS THE TIMER
In.troubleshooting.the.SUITMATE
®
.unit,.it.is.sometimes.necessary.to.bypass.the.Timer..In.this.instance,.you.
will.first.need.to.remove.the.unit.from.the.wall.as.the.Timer.is.located.on.the.back.side.of.the.unit.
Please.follow.the.instructions.beginning.on.Page.14.of.this.manual.to.remove.the.SUITMATE
®
.unit.from.the.
wall.and.to.disconnect.applicable.plumbing.and.electrical.fittings.
For.testing.purposes.only,.the.Timer.can.be.bypassed.using.the.following.procedure:
1).The.black.wire.connected.to.#2.on.the.Timer.and.the.black.wire.connected.to.COM.on.the.Timer.should.be.
....removed.off.of.the.Timer.and.wired.together.
2).After.connecting.the.two.wires.together,.restore.power.to.the.unit.and.re-test.it..If.the.issue.has.been.
....resolved,.your.Timer.needs.to.be.replaced..If.the.issue.remains,.please.consult.the.Troubleshooting.Section.
....in.this.manual.for.further.instruction.
WARNING!
Make certain the foam seal on the Micro Switch Box Cover is not damaged so
that water cannot enter the Micro Switch Box.