Other waveforms: 1
μ
Hz~50MHz
Resolution: 1
μ
Hz or 12 digits
Accuracy:
±
1ppm
±
1
μ
Hz 0
℃
~40
℃
Aging rate:
±
1ppm/year
5.1.10 Amplitude(50
Ω
load, offset 0Vdc)
Range: 1mVpp~10Vpp frequency≤40MHz
1mVpp~5Vpp frequency
≤
100MHz
1mVpp~2Vpp frequency
≤
200MHz
1mVpp~1.5Vpp frequency
≤
300MHz
1mVpp~1Vpp frequency>300MHz
Resolution: 1mVpp or 3digits
Accuracy: (Sine 1kHz,
≥
10mVpp, high impedance):±(of settings value×1%
+
1mV)
Flatness: (Sine 0dBm
,
relative to 10MHz):
±
0.2dBm frequency<100MHz
±
0.3dBm frequency<200MHz
±
0.4dBm frequency<300MHz
±
0.5dBm frequency
≥
300MHz
Unit (Sine) : Vpp, Vrms, dBm
5.1.11 DC offset (50 Ω load) :
Range:
±
5Vpk(ac
+
dc)
Resolution: 1mVdc
Accuracy(High-Z):
±
(|setting value|×1%
+
2mV
+
amplitude value ×0.5%)
5.1.12Polarity and Phase
Output Polarity: positive or negative
Output Phase: 0°to 360° (compared to sync)
5.1.13 Signal Output
Output impedance: 50Ω (typical value)
Output protection: overload automatically disables main output
Port grounding: The signal is isolated from the case