Suiden SS-22DD-8A Instruction Manual Download Page 5

4

 

4 Setup

Important: To ensure safety, read section one “ 1

  For your safety!“ first.

1. Placing the unit

Make sure that the unit is placed so that there is nothing blocking the front 
side filter, the cool air duct or the hot air exhaust duct. 
There is only an air inlet on the front side, and the only air outlets are on 
the top, so the unit can be placed with the other sides directly against a 
wall, in a corner or in any other confined space.

2. Attaching the cool air duct

(1) Attaching the duct elbow

I. 

Insert the duct elbow into the elbow holder, fitting the attach

-

ment notch to the black mark on the inside of the holder.

II. 

After you have inserted the duct elbow into the holder, fasten 
it so does not come loose by turning it to either side.

∆ 

Note: 

Make sure that the duct elbow is correctly inserted into the 
holder. If the duct elbow is not attached evenly, reattach it 

correctly. 

(2) Attaching the cold air duct

I. 

Insert the cold air duct into the duct elbow, fitting the attach

-

ment peg on the duct to the attachment notch in the elbow, 
then turn it to the right.

 

Be sure not to insert the end with the screws!

II. 

Point the duct in the direction you want the air to blow in, fix

-

ing the duct elbow with your other hand.

 

*

 Please see page 8 for more information.

(3) Removing the duct elbow

I. 

Remove the cool air duct from the elbow.

II. 

Turn the elbow until the attachment notch is aligned with the 
insertion mark.

III. 

Remove the duct elbow by pulling it straight up from the 
holder.

∆ 

Note:  

Do not use the unit in places containing hydrochloric acid, sulphuric acid or any other corroding gas or steam.

 

*

There is risk of gas leak or deterioration of performance.

≥30cm

≥30cm

≥ 40cm

Insert

Duct elbow 

insertion mark

(Black line)

Duct elbow 

attachment notch

Filter

Duct elbow

Attachment notch

Attachment peg

Screw

 

Insertion mark

(Black line)

Attachment 

notch

Duct elbow

Summary of Contents for SS-22DD-8A

Page 1: ...0 After service 14 Index Thank you for purchasing this product from the world brand SUIDEN Please use this product correctly after having thoroughly read this manu al After having finished reading ple...

Page 2: ...in water leakage and a short circuit Testing and operating the unit Warning Please do not use the unit close to kerosene gasoline thinner ether paints or other flammable or explosive objects This can...

Page 3: ...e unit if the cord or plug is damaged or if the plug is loose in the socket Electric shock or fire caused by a short circuit can occur If you use an extension cord make sure to use one that meets the...

Page 4: ...use it instead Caster wheel with brake Drain tank Filter cover Electric cord earthed 2 0m complete with plug Caster wheel Earth terminal Service box Handle Control panel Filter Interior part Filter e...

Page 5: ...uct elbow is not attached evenly reattach it correctly 2 Attaching the cold air duct I Insert the cold air duct into the duct elbow fitting the attach ment peg on the duct to the attachment notch in t...

Page 6: ...parts and cause malfunction Do not block the exhaust air vent in any way This will obstruct the function of the unit and cause malfunction Note If you will make an opening for the duct extension in th...

Page 7: ...extension to the cool air duct narrow the end until the gap is completely sealed then tighten the duct strap III Attach the accessory cool air duct extension cap onto the duct extension with glue Atta...

Page 8: ...stment switch and the swivel switch to make sure that everything works properly I The properties of all the switches are explained further in the next section How to use II If the unit does not work p...

Page 9: ...ed approximately 300 degrees Vertical adjustment The cool air duct is flexible and can be bent in any desired way within its possible range Note I Bend the cool air duct gently firmly holding the duct...

Page 10: ...r cold part of the heat exchanger on the front of the unit vaporises when it passes through the warm lower part on the way down to the drain tank In certain environments almost all water will vapor iz...

Page 11: ...relay protects the compressor from overcurrents and overheating engine II The compressor overload relay is automatic If the overload relay starts to work frequently and the unit stops working please t...

Page 12: ...oil mist filter prevents deterioration of cooling effect caused by the heat exchanger becoming greasy and prevents the condensed water from scattering 2 External maintenance I Wipe the ducts and other...

Page 13: ...not install it correctly Is the filter torn or damaged Change it for a new one Is the fin of the heat exchanger broken Hand the unit in for inspection and repair at your local retailer Is the heat ex...

Page 14: ...fore turning on the COOL again This does not apply to AIR which can be turned on immediately Is the voltage too low Consult with your electric company The unit turns itself on and off frequently The o...

Page 15: ...you commence Inaccurate or inappropriate use can cause the quality of the objects to deteriorate Sometimes it will be necessary to perform installation work and electric work to the unit In these cas...

Reviews: