Rev.01
– 11/01/2021
Pag. 14/20
Code: 71380
Provision must be taken ALONG THE ENTIRE LIFE OF THE BATTERY (warehouse storage, transfer etc.
included) to ALWAYS ensure that:
•
The batteries are stored fully charged mostly when they are not expected to be used for a long time.
•
The batteries are fully charged at least every 2 months.
•
The batteries are fully charged in any case when the charge level is below 20%.
Suex cannot be held responsible for any loss or damage to the battery resulting from failure to follow the
instructions contained in this manual.
17.
MESSAGES, PROBLEMS, CAUSES AND REMEDIES
The below list mentions all the error messages that could appear on the BATTERY display together with their
meaning and corresponding behaviour to be adopted in the circumstance.
Strictly observe the following list:
AUTO OFF - BATTERY IN STANDBY MODE:
The "AOFF" message informs that the battery is in the auto off state: this low
energy consumption condition occurs in the normal behaviour after a few hours
of in use and it is part of the normal functioning.
When the "AOFF" message appears on the display - also accompanied with the
bell sign - alternate with the SOC value the situation is fully normal and IT IS
NOT AN ALARM.
To wake up the battery and turn it on connect to a load (i.e. to the battery
charger or to the DPV acting on the trigger for 5 seconds).
BATTERY PACK UNDER CHARGING PROCESS:
verify the correct charger is being used
BATTERY PACK UNDER DISCHARGING PROCESS:
verify amp load
FIRST SHORT CIRCUIT:
wait 30 minutes
SECOND SHORT CIRCUIT:
wait 60 minutes
Since the electronic circuits on board the battery have their own internal energy
consumption - negligible but NOT NULL - every care must be taken by the user
to prevent that during prolonged periods of inactivity the batteries may suffer
damage, even irreversible, to due to excessive cell discharge.
In a preventive perspective, in order to avoid that the aforementioned practice is
not followed - with possible IRREVERSIBLE damage to the battery - during ANY
logistic phase after the supply of the goods, SUEX s.r.l. hereby would like to
emphasize the INFORMATION for the customer's organization, in particular for
those responsible for warehouse management regarding the NEED TO PERIODIC
CHARGE of the batteries.
The above applies to the BATTERY PACKS supplied as accessories or spare
parts and those inside the Scooters.