background image

 

 

 

 

 

 

 

SETTINGS 

CLOCK 

 

LANGUAGE 

 

ADVANCED 

 

 

 

 

 

 

 

 

 

 

 

 

BRIGHTNESS 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERMANENT 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOLIDAYS 

 

 

 

 

 

 

 

 

 

 

 

 

 

METERS 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEASON 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN CODE 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 H / 24 H 

 

 

 

 

 

 

 

 

 

 

 

 

 

VERSION 

 

 
PROGRAMS.

 This is the menu where the different operations are programmed. There are 40 

memory spaces (P-01 to P-40). 
 

 

ENTER.

 We enter by pressing 

, and with the 

 and 

 keys we move through the different 

programs stored in the memory.  
When entering this menu, if any programs have already been stored, the first program that was 
stored appears in the display text line: “P-01”, and with the 

 key we can go up the different 

stored programs until we reach the first empty program, in which the display text line will show “P-
XX EMPTY” alternating with the number of programs available left in the memory of the device.  
When entering this menu, if no other programs have been created, the display text line will show: 
“P-01 EMPTY” alternating with “40 LEFT” referring to the memory spaces available.  
If we wish to modify or create a program we move to it with the 

 and 

 keys, and press 

. Next, 

with the 

 and 

 keys we select one of the following options:  

-

  EDIT. This option allows us to choose the type of operation that will be performed in the 

selected program. By pressing 

, “ON TYPE” will be displayed and with the 

 and 

 keys we 

can choose the type of operation. The operations can be: 

  ON TYPE. Switch-on of the connected circuit at a fixed time. 

  OFF TYPE. Switch-off of the connected circuit at a fixed time.  

  CYCLE TYPE. ON and OFF operations performed repeatedly from beginning to end. To 

program the beginning of the cycle we have to indicate the hour, minutes, and days of the 
week when this cycle will begin. Next, we need to specify the respective ON and OFF 
duration (in hours, minutes or in seconds). To finish, we must indicate the hour, minutes, and 
days of the week when this cycle will stop operating.  

  PULSE TYPE. Switch-on of the circuit in a pulse of a set duration at a fixed time of the day.  

Once the type of operation has been chosen, we have to select the cannel or channels it affects 
(C1, C2 or C1 + C2). 
Next, we enter the operation starting hours and the rest of the necessary times according to the 
selected operation.  

  

HOLIDAY PERIODS program  

If when validating the last day of the week with the 

 key we keep it pressed, we select this 

operation as holiday. The word HOLIDAY is displayed and with the 

 and 

 keys we select one 

of the 4 holiday periods.  

 

-

  DELETE. By pressing 

, the selected program is deleted. Since all programs are stored 

consecutively, deleting one program can change the number assigned to each one of them.  

 

 

DELETE

. This option allows for deleting all the operations of the last 40 programs in just one step.

  

 
 
 
We choose to perform the switch-on program at 10 pm  

 

 

 

 

 

 

 

 

 

 

TYPE 

 

MENU 

 

PROGRAMS 

 

ENTER 

 

P01 

 

EDIT 

 

ON 

 

 

CHANNEL  

Hour and 

min 

 

Days of the 

week 

 

 

C1 and C2 

 

22:00 

 

Mon…Sun 

 

P01 OK 

 

 
We choose to perform the switch-off program at 12 am  

 

 

 

 

 

 

 

 

 

 

TYPE 

 

MENU 

 

PROGRAMS 

 

ENTER 

 

P02 

 

EDIT 

 

OFF 

 

 

CHANNEL  

Hour and 

min 

 

Days of the 

week 

 

 

C1 and C2 

 

00:00 

 

Mon…Sun 

 

P02 OK 

 

 
We choose to perform the cycle program, with a 5-second ON and a 10-second OFF period, 
which will start at 6:00 and will finish at 8:00 during the entire week 

 

 

 

 

  

 

   

TYPE 

 

MENU 

 

PROGRAMS 

 

ENTER 

 

P03 

 

EDIT 

 

CYCLE 

 

 

CHANNEL  

FROM  

Hour and 

min. 

 

Days of the 

week 

 

ON TIME 

Hour and 

min. 

 SECONDS  

C1 y C2 

 

06:00 

 

Mon…Sun 

 

00:00 

 

05 

 

 

OFF TIME 

Hour and 

min. 

 SECONDS  

UNTIL 

Hour and 

min. 

 

Days of the 

week 

 

 

00:00 

✓ 

10 

 

08:00 

 

Mon…Sun 

 

P03 OK 

 

 

We choose to perform the pulse program, which will perform a 5-second ON period starting at 
11:30 during the entire week 

 

 

 

 

 

 

 

 

 

 TYPE  

MENU 

 

PROGRAMS 

 

ENTER 

 

P04 

 

EDIT 

 

PULSE 

 

 

CHANNEL  

Hour and 

min. 

 SECONDS  

Days of the 

week 

 

 

C1 and C2 

 

11:30 

 

05 

 

Mon…Sun 

 

P04 OK 

 

 
 

 
SETTINGS.

 This is the menu where we configure the device.  

 

 

CLOCK

. Sets the time of the device. The variables to configure are (in this order): Year, month, 

day, hour and minute. The day of the week is calculated automatically. 

 

 

LANGUAGE. 

This is the menu where the language of the device is selected.  

 

ADVANCED. 

This is the menu where most of the device configuration can be done.

  

-

  BRIGHTNESS. Menu where we can select the brightness of the display. MINIMUM, LOW, 

MEDIUM, HIGH, or MAXIMUM. The brightness on screen will be adjusted if we validate the 
visualised level.  

-

  PERMANENT. The menu where we can set a permanent operation (ON or OFF) of channel C1 

and channel C2. With the 

 and 

keys we move through the different options: C1: YES 

 C1: 

NO 

 C2: YES 

 C2: NO. We validate with 

 our desired option. The device will not take 

notice of the operation programming for the selected channel if we choose the YES OPTION.  

-

  The contact position can be changed manually (see MANUAL OPERATION) 

-

  HOLIDAYS. It has 4 PERIODS that can be programmed to perform the operations selected in 

the programming of HOLIDAY PERIODS. If no operation is programmed in a period, the 
channels will remain OFF during said period. PERIOD 1 …4 

  EDIT. The month, day, hour and minute of the beginning of the period and the month, day, 

hour and minute of the end of the period are programmed. This period will be repeated 
year after year.  

  DELETE. The selected period is deleted.  

-

  METERS. Menu where the switch-on time of each circuit is indicated (in hours). Accessing the 

meter of each channel with 

, they can be set to zero. Select DELETE YES and validate.  

-

  SEASON. Allows for adjusting the time change from daylight saving to standard time and vice 

versa.  

  ACTIVE. Automatically makes the time change from daylight saving to standard time or 

vice versa, in accordance with each country’s legislation. (EU the last Sunday of March and 
the last Sunday of October) 

  INACTIVE. Does not make the time change.  

-

  PIN CODE. Menu to activate or disable the keyboard lock to prevent unwanted access to the 

device settings.  

  INACTIVE. Keyboard lock disabled.  

  ACTIVE. Keyboard lock activated. And we are required to program a four-figure PIN 

CODE. This protection will be activated 30 seconds after we come out of the settings and 
return to the display in standby mode. From that moment on when any key is pressed the 
message “PIN CODE” will appear on screen. To unblock the access to the device, we will 
need to enter the PIN CODE programmed in its activation. The device will be unblocked for 
10 seconds. During this time we will be able to access the settings menu by pressing 

After 30 seconds without handling the device, it will get locked again.  

-

  12H – 24H. With the 

 and 

keys we select the mode in which we wish to see the time. We 

validate the selection with 

 

-

  VERSION. Menu where the software version of the device is shown.  

 

If simultaneous operations are programmed we have to take into account that some have priority 
over the others. The priority order is as follows:  

PERMANENT MODE 

 MANUAL 

 PROG_01 

 PROG_02 

 …. 

 PROG_40 

 

RESET. SET TO ZERO.  

Starting on standby mode (main screen), press the 

C

 key and while keeping it pressed press the 

 

and 

 keys simultaneously for more than 3 seconds. The display gets turned off, all programming is 

deleted. The device must be powered.  
We can also perform a quick deletion that does not affect the programming by pressing the four keys 
simultaneously. The device must be powered.  

 

BATTERY CHANGE. FIG.4 

The device has a power-reserve of 4 years, by means of a replaceable CR2032 lithium battery. 
Battery replacement is made by removing the battery holder placed on the front of the device through 
a flat-head screwdriver. Observe the battery polarity as marked on the battery holder. 
When the battery is dead and the device is powered the battery symbol appears on screen.  
NOTE: When changing the battery the device’s programming is not lost, and neither is the current time. 

TURN OFF THE POWER SUPPLY TO REPLACE THE BATTERY 

 

TECHNICAL FEATURES 

Rated voltage and frequency  

As indicated in the device 

Resistance  

± 10% 

Breaking capacity: 

µ 2x16 (10) A / 250 V~    

Maximum recommended loads (N.A): 

FIG.3

 

Own consumption 

16 VA (1.3 W) maximum 

Contact AgSnO

2

  switched.   

Display screen  

Back-lit LCD 

Running accuracy 

± 1 s / day at 23 ºC 

Accuracy variation with temperature 

± 0.15 s / ºC / 24 h 

Power reserve 

4 years (with battery and no network connection) 

 

48 h (no battery and no network connection) 

Type of action 

1S, 1T, 1U  

Software class and structure 

Class A 

Memory spaces 

40 

No. of channels 

1 channel DigiLog; 2 channels DigiLog 2 

Types of operations 

ON/OFF, PULSE (1 to 59 sec.) and CYCLES (1 to 59 sec. 
or 1 min to 23h and 59 min). 

Astronomical adjustments  

± 1 second 

Operating temperature  

-10 ºC at +45 ºC 

Transport and storage temperature 

-20 ºC at +60 ºC 

Pollution situation 

Protection level  

IP 20 according to EN60529 

Protection class 

II under correct mounting conditions 

Transient impulse voltage 

2.5 kV 

Temperature for the ball test 

+ 80 ºC for 21.2.5 

Keyboard access cover 

Sealable 

Connection 

With screw terminal for wire cross section of up to 4mm² 

Battery 

CR2032 - 3 V - 220 mAh 

Wrapping size 

2 DIN modules (35 mm) 

FIG.5

 

 
 

WARNING: 

This time switch includes a battery whose contents may be damaging to the environment. Do not get 
rid of the product without taking the precaution of dismantling the battery and placing it in an 
appropriate recycling container, or sending the product back to the factory. 

 
 

Summary of Contents for DigiLog

Page 1: ...r ft werden dass das zusammengestellte System keine parasit ren St rungen hervorruft STROMZUFUHR WIEDERHERSTELLEN WENN DAS GER T VOLLKOMMEN INSTALLIERT IST MONTAGE Elektronisches Kontrollger t f r una...

Page 2: ...Wenn wir OPTION JA w hlen ignoriert das Ger t die Programmierung der Aktionen f r den gew hlten Kanal Der Kontakt kann manuell umgeschaltet werden siehe HANDBETRIEB FEIERTAGE Es k nnen 4 Perioden prog...

Page 3: ...constitu ne g n re pas de perturbations parasites R TABLIR L ALIMENTATION QUAND L QUIPEMENT SERA TOTALEMENT INSTALL MONTAGE Dispositif de contr le lectronique de montage Ind pendant dans une armoire d...

Page 4: ...L quipement ne fera aucun cas de la programmation de man uvres pour le canal s lectionn en cas de choisir l OPTION OUI On peut changer la position du contact manuellement voir ACTIONNEMENT MANUEL F R...

Page 5: ...ANNING BRENGEN WANNEER DE UITRUSTING VOLLEDIG GE NSTALLEERD IS MONTAGE Inrichting voor elektronische bediening met onafhankelijke montage in een distributiekast uitgerust met een symmetrisch profiel v...

Page 6: ...voeren in de programmering VAKANTIEPERIODES Ingeval in een periode geen enkele transactie wordt geprogrammeerd dan blijven de kanalen in deze periode in de stand UIT PERIODE 1 4 BEWERKEN De maand de d...

Page 7: ...hould be made sure that the constituted unit does not generate extraneous disturbances RESTORE SUPPLY ONCE THE DEVICE IS FULLY INSTALLED MOUNTING Electronic control device of independent mounting in f...

Page 8: ...operation programming for the selected channel if we choose the YES OPTION The contact position can be changed manually see MANUAL OPERATION HOLIDAYS It has 4 PERIODS that can be programmed to perform...

Reviews: