protection and care 

All parts of the unit are build in anodized seawater resistant aluminium or plastic.  
It is recommended anyway, to wash the unit after a saltwaterdive with fresh water.
This is particularly valid for the operating board. The synchronous cable should be 
removed only after rinsing from the camera. 

 

NEVER   DIP   THE   EQUIPMENT   WITHOUT   CAP   ON   THE   SYNCHRONOUS   - 
PLUGS INTO THE WATER 

change of the seal-rings 

We   recommend   to   send   the   unit   back   to   us   for   service   after   approx.   5   years,
for changing the seal-rings. The seal-rings on the NIKONOS connector can be checked 
and if necessary changed by yourself.                                                                                                               

Windings and seal-rings of the connectors should always be  greased 
slightly

 

.

control of the cables

The coiled cables are sea water resistant and requires no special care. However these 
cables should be checked regularly, particularly after air passage, for cuts and tears, in 
order   to   avoid   penetration   of   water   in   the   cable   and   thus   in   the   camera   or   lightning 
housing. 

  

Always pack the flash with unmounted cable

With improper inserted connectors in lightning and/or camerahousing water can arrive at 
the socketcontacts. The sockets are inward sealed, so that no water can arrive in the flash 
appartus, even if the cables are not correctly fastened. 
Make   sure   that   the   locknut   of   the   plug   is   always   turned   back   when   putting-in.  
pre-turn the locknut only after tightening the connector. It is important, that the plug rests 
upon   plane   the   camera   lower   surface.   The   connector   may   not   be   impaired   by   the 
mounting plate in its seat. Because thus on the one hand the camera can be damaged. 
On the other hand the water can penetrate with larger depths in the cable. So that in the 
course of the time the connections in the plug corrodes and the equipment does not work 
any longer. 
In addition small quantities of seawaters between the contacts can lead to false trigger 
signals. If the equipment should ignite when switching on on, then the reason for it is to be 
nearly always found at the plug connector. 

Check the connector and the seal rings before each dive.

Place your housing and flash in such a way that they do not press on the cable 
connections! 

Broken wires results mainly from to strong course at the cable. Look that the cable 
under water never catch in something.

Use only the connectors at the cable to connect. If you skew the cable, broken wires 
can be a result.

9

Summary of Contents for Pro 160 Fusion

Page 1: ...3 2010 1 user manual user manual...

Page 2: ...ER STEPS 8 PROTECTION AND CARE 9 CABLE CONNECTIONS 10 FLASH ARM CONNECTOR 10 FORM UP THE FLASH CAPACITOR 11 TTL CHECK 11 LEAKAGE ON THE HOUSING 11 SAFETY INSTRUCTIONS 12 IMPORTANT NOTES FOR DIVING TRI...

Page 3: ...rsion TTL analog Ixx I TTL Exx E TTL Oxx Olympus version TTL analogue Ixx I TTL Exx E TTL Oxx Olympus ready lamp mode switch pilot push button accu connector synchronous connector ready lamp mode swit...

Page 4: ...weight They have no MEMORY effect The accumulator haven t need to be unloaded before charging insert the S4 connector from the charger in the connector from the external accumulator system Please cons...

Page 5: ...f the unit always before you connect or disconnect accu tank deep charge protection In the case of falling voltage below working voltage the electronic switches off the pilot lamp and or the flash Thu...

Page 6: ...mera As soon as the flash is connected with a analogical camera the ready symbol in the camera lights up after touching the trigger lightly Strongly reflecting objects as well as back light photograph...

Page 7: ...unction a digital converter is absolutely necessary Depends on the underwater housing manufacturer or model the converter is already integrated to the camera housing Please ask therefore your the manu...

Page 8: ...r your camera supports manual flashes functionality the flash delivers in manual mode a constant lightning energy These power steps are controlled by the integrated computer and therefore every time i...

Page 9: ...ing water can arrive at the socketcontacts The sockets are inward sealed so that no water can arrive in the flash appartus even if the cables are not correctly fastened Make sure that the locknut of t...

Page 10: ...tive cable or defective connectors water can break in the system NEVER DIP THE UNITS WITHOUT CAPS OR MOUNTED CABLES INTO THE WATER flash arm connector The flash arm connector on the bottom side of the...

Page 11: ...leakage on the housing If water penetrates into the flash gun body please follow the instructions below Switch off the device Remove the rear cap ring this ring doesn t have a sealing function but is...

Page 12: ...by untrained technicians Do not open the flash gun There is a risk of leakage if the device is reassembled incorrectly The electronics will be destroyed immediately if salt water penetrates into the...

Page 13: ...mage Pack the device in a robust cardboard box with plenty of room on all sides for padding material Do not use a shoe box Detach the flash gun arm covers and other removable parts from your device Pl...

Page 14: ...version automatic camera identification for NIKON CANON PENTAX TTL mode digital only digital version by internal converter or as analogue model by external converter preflashes max 20 kHz ready lamp...

Page 15: ...digital version by internal converter or as analogue model by external converter preflashes max 20 kHz ready lamp by LED yes slave mode external trigger unit optional pilot lamp 3 area LED modules in...

Page 16: ...l defect shall either be repaired free of charge or replaced should the repair costs be disproportionately high A more extensive liability is excluded subtronic shall not be liable for indirect damage...

Page 17: ...dress Model Serial number contents of parcel Charger Accu Synccord caps quantity______ others ______________________ Error description normally we need 14 days for standard repairs For repairs which m...

Page 18: ...ess Office Mo Fr 9 00 12 00 and 13 00 16 00 Tel 0049 0 7023 74669 0 Fax 16 E mail service subtronic de visit us in Internet http www subtronic de 18 Michael Becker Strasse 9A D 73235 Weilheim Deutschl...

Page 19: ...dress Model Serial number contents of parcel Charger Accu Synccord caps quantity______ others ______________________ Error description normally we need 14 days for standard repairs For repairs which m...

Page 20: ...d 13 00 16 00 Tel 0049 0 7023 74669 0 Fax 16 Email service subtronic de visit us in Internet http www subtronic de Your Subtronic Dealer serial number date of delivery 20 Michael Becker Strasse 9A D 7...

Reviews: