start-up
check before inserting the camera into the camerahousing the hotshoe, as well as all
cable connections in the camerahousing for mechanical damages. Broken wires
and/or bad contacts in the feeder lines can lead to malfunctionings or damage to
camera or flash appartuses.
Connect the S4 plug with the
left
S4 socket at the flash.
The right synchronous connection is N5 bulkhead and will connected with camera
housing.
The contacts can be connected easily without use of force.
Turn the mode switch in auto position. the flash will start working and load the capacitors.
After 2-3 seconds the ready light appears. The unit is now ready to work. If there is no
reaction after approx. 10 seconds, you have to switch of the unit and charge the accu.
to save the unit from a loss, switch off the unit always before you connect or
disconnect accu-tank.
deep charge protection
In the case of falling voltage below working voltage the electronic switches off the pilot
lamp and/or the flash. Thus the accu cannot be deeply unloaded, which benefits the life
span. Switches off the equipment and charges the external accumulator soon.
Note:
never storage the flash with connected accu!
be sure, that the accu is charged before storaging.
Over temperature protection
your
pro160
is fitted with a thermal protection circuit.
If the temperature in the unit is higher than the allowed operating temperature f.e. by to
short flashcycles ore other negative impacts, the processor will switch off the high voltage
circuit immediately.
In this case the ready indicator on the backplate starts blinking.
On analogical flashes the ready indicator in the camera blinks too.
The flash do not fire during this process.
If the temperature in the unit in the allowed area the flash restarts immediately