– 21 –
(2)
Check if the surge absorber is burnt.
Check the resistance of surge absorber.
(3)
Measure the resistance of the diode.
8-5 CONDENSER
■
If an instrument (QC-meter or C-meter) for mea-
suring capacity of condenser is available, check
the capacity of condenser.
■
If such an instrument is unavailable, the condenser can be checked by replacing with a new one. If the
generator performs good with new condenser, the cause of trouble is defect in original condenser.
Normal resistance is
∞
Ω
.
NORMAL CAPACITY OF CONDENSER
MODEL
RGD3300H
RGD5000H
60 Hz
60 Hz
CONDENSER
20 µF
30 µF
20 µF
30 µF
[Continuity exists.]
POLARITY OF
CIRCUIT TESTER
POLARITY OF
CIRCUIT TESTER
CONDENSER
1
2
GENERATOR_GS2380.fm 21 ページ 2007年10月1日 月曜日 午前9時13分
Summary of Contents for ROBIN RGD3300H
Page 1: ...SERVICE MANUAL RGD3300H RGD5000H GENERATORS Models PUB GS2380 Rev 06 08 ...
Page 2: ......
Page 53: ......