Subaru ROBIN PUMP PKV401T Instructions For Use Manual Download Page 16

9

ENGLISH

FRANÇAISE

ESP

AÑOL

1. WATER (See Fig.

8

8

8

8

8

-

q

q

q

q

q

)

Drain all water from the drain plug.

6. PREPARATIONS FOR STORAGE

If you do not use the engine more than 1 month, discharge
fuel to prevent gum in the fuel system and carburetor parts.

 

Remove the strainer cup, place the strainer over a

container and open the strainer cock to discharge fuel
from the fuel tank.

 

Remove the drain screw of the carburetor float  chamber

and discharge fuel.

4. ENGINE OIL (See Fig.

8

8

8

8

8

-

e

e

e

e

e

)

 

Change the engine oil with fresh oil.

 

Remove the spark plug, pour about 5 cc of engine oil
into the cylinder, slowly pull the starter handle of the
recoil starter 2 or 3 times, and reinstall the spark plug.

5. CLEAN AND STORE

 

Slowly pull the recoil starter handle until resistance is
felt and leave it in that position.

 

Clean the pump thoroughly with an oiled cloth, put the
cover on, and store the pump indoors in a well ventilated,
low humidity area.

When retightening drain plug, be sure to clean
the drain plug and the thread of casing.
Otherwise, the thread may be damaged.

CAUTION

2. DISCONNECT THE DELIVERY HOSE

Tilt the pump and drain all water from delivery hole. Severe
damage to pump may result if water freezes in the pumping
chamber.

WARNING

Flame Prohibited

3. DISCHARGE FUEL  (See Fig.

8

8

8

8

8

-

w

w

w

w

w

)

1. FUNCTION OF OIL SENSOR

The engine will stop automatically when the oil level
falls below the safety limit. The engine cannot be
started unless the level is raised above the prescribed
limit. (See Fig.

2

-

r

)

2. RESTARTING (See Fig.

8

8

8

8

8

-

r

r

r

r

r

)

q

 Oil sensor

(1) Fill the crankcase with oil up to the proper level.

(2) As for restarting and operating the engine, refer to

section 

“4. OPERATING YOUR PUMP”

 on page 6.

Check the wire connector from the engine. It must be
connected securely to the wire from oil sensor.

When selecting the engine oil, refer to page 5 for the
recommended oil.

7. OIL SENSOR INSTRUCTIONS

(OPTIONAL)

■ 

Prevents the flow of exhaust gas

■ 

Reduces engine output

■ 

Increases fuel consumption

■ 

Makes starting difficult

If the engine has been running, the muffler and the spark
arrester will be very hot. Allow the muffler to cool before
cleaning the spark arrester.

How to remove the spark arrester

1.  Remove the flange bolts from the muffler cover and

remove the muffler cover.

2.  Remove the special screw from the spark arrester and

remove the spark arrester from the muffler.

Clean the spark arrester screen

Use a brush to remove carbon deposits from the spark
arrester screen. Be careful to avoid damaging the screen.
The spark arrester must be free of breaks and holes.
Replace the spark arrester if it is damaged.

Install the spark arrester, and muffler protector in the
reverse order of disassembly.

1. SPARK ARRESTER

In a dry or wooded area, it is recommendable to use the
product with a spark arrester. Some areas require the use
of a spark arrester. Please check your local laws and
regulations before operating your product.

The spark arrester must be cleaned regularly to keep it
functioning as designed. A clogged spark arrester:

8. SPARK ARRESTER

(OPTIONAL)

SPARK ARESSTER SCREEN

SPARK 

ARRESTER 

SCREEN

MUFFLER

MUFFLER COVER

PKV401T(US)̲PU2255.pmd

06.10.20, 8:09 PM

Page 9

Adobe PageMaker 7.0J/PPC

Summary of Contents for ROBIN PUMP PKV401T

Page 1: ...PKV401T 9ZZ9990043...

Page 2: ...4 5 6 5W 10W 20W 20 30 40 10W 30 10W 40 Single grade Multi grade Ambient temperature 20 10 0 10 20 30 40 C 4 14 32 50 68 86 104 F 2 3 1 6 1 2 1 2 1 2 2 2 1 1 21 20 23 1 4 3 2 1 17 18 19 2 3 4 5 6 7 8...

Page 3: ...7 4 1 2 1 2 0 7 0 8 mm 5 1 2 4 4 3 5 1 2 1 2 4 3 3 1 2 2 6 8 1 2 3 4 6 1 1 L L H H L 2 1 1 2 8 3 1 5 7 2 6 4...

Page 4: ...es other than the U S A warranty service shall be performed by the distributor in each country in accordance with the standard Robin engine generator warranty policy as applicable To show compliance w...

Page 5: ...amages such as loss of time inconvenience loss of use of the engine or equipment etc Diagnosis and inspection charges that do not result in warranty eligible service being performed Any non authorized...

Page 6: ...d to an ultimate purchaser or first placed into service The warranty period is two years b Subject to certain conditions and exclusions as stated below the warranty on emissions related parts is as fo...

Page 7: ...justment limiting device is still eligible for warranty coverage The following emissions warranty parts list are covered 1 Fuel Metering System A Carburetor and internal parts and or pressure regulato...

Page 8: ...ecifications are subjected to change without notice When ordering spare parts always give us the MODEL PRODUCTION NUMBER and SERIAL NUMBER of your pump Please fill in the following blanks after checki...

Page 9: ...te the pump while smoking or near an open flame Do not use around dry brush twigs cloth rags or other flammable materials Keep cooling air intake recoil starter area and muffler side of the engine at...

Page 10: ...ngerous situation Check bolts and nuts for looseness A loose bolt or nut may cause serious engine trouble Check the engine oil and refill if necessary Check the fuel level and refill if necessary Take...

Page 11: ...r use This publication Read the owner s manual Stay clear of the hot surface Exhaust gas is poisonous Do not operate in an unventilated area Stop the engine before refueling Fire open flame and smokin...

Page 12: ...g 2 2 2 2 2 r r r r r Before checking or refilling engine oil be sure the engine is located on stable level surface and stopped Do not screw the oil gauge into the oil filler neck to check oil level I...

Page 13: ...speed control lever toward the high speed position H and set it at the required engine speed See Fig 4 w Whenever high speed operation is not required slow the engine down idle by moving the speed con...

Page 14: ...ge is found replace the pipe immediately CAUTION Periodic Maintenance Schedule table MS2234 Maintenance Items Note 1 Initial oil change should be performed after first twenty 20 hours of operation The...

Page 15: ...ent clean Air cleaner paper element and urethane foam can be take out after removing knob and air cleaner cover When installing set the paper element and urethane foam on the air cleaner base Be sure...

Page 16: ...r 2 RESTARTING See Fig 8 8 8 8 8 r r r r r q Oil sensor 1 Fill the crankcase with oil up to the proper level 2 As for restarting and operating the engine refer to section 4 OPERATING YOUR PUMP on pag...

Page 17: ...n I ON Remove and inspect the spark plug If the electrode is fouled clean or replace it with new one Remove the spark plug and connect it to the plug cap Pull the starter handle while grounding spark...

Page 18: ...Clearance Intake and Exhaust Emissions Durability Period California only Silicon carbide EH41D 1 2 0 32 Air cooled 4 cycle Single cylinder Horizontal Shaft Gasoline Engine 4 Stroke automotive deterge...

Page 19: ...ISSUE EMD PU2255 PRINTED IN JAPAN October 2006...