Page 27
OUTDOOR B
BBQ G
GRILLS
Component Removal
Valve Adapter and Tee
The valve adapter is threaded onto the end of the infrared rotisserie burner valve. It allows the tee adapter to be
threaded on, so the rotisserie burner valve can supply gas to the pilot valve and the safety valve for the infrared
burner. To remove the valve adapter you will need to turn off the gas supply, remove the control knobs, control
panel and unplug the spark electrode wires from the rotary igniter. Now, loosen and remove the pilot valve gas tub-
ing from the pilot valve and loosen and remove the gas tubing from the safety valve to the connector on the tee
adapter. Then loosen and remove the entire valve adapter/tee assembly as one unit. Once the assembly has been
removed from the unit, remove the valve adapter from the tee.
Nipple and Connector
The nipple is threaded on the end of the tee, which allows the connector for the flexible gas tubing to be threaded
on. This flexible gas tubing goes to the safety valve which supplies gas to the infrared burner. To remove the nipple
you will need to turn off the gas supply, remove the control knobs, control panel and unplug the spark electrode
wires from the rotary igniter. Now you will need to loosen and remove the pilot valve gas tubing from the pilot valve
and loosen and remove the gas tubing from the safety valve to the connector on the tee adapter. Now loosen and
remove the entire valve adapter/tee assembly as one unit. Once the assembly is removed from the unit, you can
remove the nipple from the connector and the tee.
Pilot Valve
The pilot valve is threaded into the bottom of the tee. It allows for a separate gas supply to go to the pilot light for
the infrared burner. To remove the pilot valve you need to turn off the gas supply, remove the control knobs, control
panel and unplug the spark electrode wires from the rotary igniter. Now you will need to loosen and remove the pilot
valve gas tubing from the pilot valve and loosen and remove the flexible gas tubing from the safety valve to the con-
nector on the tee adapter. Now loosen and remove the entire valve adapter/tee assembly as one unit. You can now
loosen and remove the pilot valve from the tee.
Manifold Pipe
The manifold pipe is connected to the gas source at one end and is sealed at the other end. It supplies gas to the
burner valves, pilot valve and safety valve. To remove the manifold you need to turn off the gas supply, remove the
control knobs, control panel and unplug the spark electrode wires from the rotary igniter. Now you will need to
loosen and remove the pilot valve gas tubing from the pilot valve and loosen and remove the flexible gas tubing from
the safety valve to the connector on the tee adapter. Now disconnect the manifold from the gas source. Extract the
screws that secure the manifold to the grill chassis and remove the manifold by pulling straight out of the grill chas-
sis.
Manifold Pipe
Tee
Pilot Valve
Connector
Nipple
Valve Adapter
Rotisserie Burner Valve
Grill Burner Valve
Fig. 4-24