background image

Planning Information

30"

(762)

Sealed Burner Rangetop

Dimensions in parentheses are in
millimeters unless otherwise specified.

4

D I M E N S I O N S

Rough Opening Width

30" (762)

Rough Opening Height

7

1

/

2

" (191)

Rough Opening Depth

24" (610)

Location of Electrical and Gas Supply

Within shaded area

See Installation Instructions shipped with unit for detailed specifications.

VENTILATION

HOOD

30"

 (762)

OPENING WIDTH

30"

min (762)

TO

 36"

max (914)

TO BOTTOM OF

VENTILATION HOOD

30"

min (762)

COUNTERTOP

 TO COMBUSTIBLE

MATERIALS

     3

/

4

(19)

PLATFORM

TOP VIEW

OF PLATFORM

E

G

16"

(406)

16"

 (406)

4" 

(102)

BACK
WALL

ISLAND INSTALLATIONS: 12" (305) MINIMUM

CLEARANCE FROM BACK OF RANGETOP TO

COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–

0" (0) TO NON-COMBUSTIBLE MATERIALS

LOCATION OF GAS AND

ELECTRICAL SUPPLY CUT-OUT

WITHIN SHADED AREA

THROUGH BOTTOM OF

PLATFORM

36"

(914)

18"

min (457)

TO COUNTERTOP

3

/

4

(19)

PLATFORM

 8

1

/

2

"

(216)

COOKING
SURFACE

 7

1

/

2

"

(191)

24" 

(610)

13"

max

(330)

6"

min (152)

TO

COMBUSTIBLE

MATERIALS

(BOTH SIDES)

I N S T A L L A T I O N S P E C I F I C A T I O N S

Summary of Contents for SRT304

Page 1: ... higher settings the lower tier continuous flame ably handles the subtleties of simmering and melting These rangetops offer you that commercial look but give you flexibility to use the ovens in other locations in the kitchen In fact the Wolf framed ovens would be a beautiful complement to these cooking instruments Let Wolf the corporate companion and kitchen soul mate of Sub Zero fuel your passion...

Page 2: ...rface burners all with simmer capabilities and automatic reignition at all settings 15 000 Btu hr 4 4 kW burners with 950 Btu hr 3 kW delivered at simmer 9 200 Btu hr 2 7 kW burner with 325 Btu hr 1 kW delivered at simmer and melt feature Certified by Star K to meet religious regulations CSA certified for US and Canada Two and five year residential warranty exclusions apply warranty information ca...

Page 3: ... kg Specifications are subject to change without notice M O D E L O P T I O N S Four Burners SRT304 Natural gas model listed for LP gas add LP to the model number V E N T I L A T I O N O P T I O N S 30 762 Pro wall hood or liner 36 914 Pro wall or island hood Refer to the Wolf Pro Ventilation section of our website wolfappliance com for additional information A C C E S S O R I E S 5 127 or 10 254 ...

Page 4: ... min 762 TO 36 max 914 TO BOTTOM OF VENTILATION HOOD 30 min 762 COUNTERTOP TO COMBUSTIBLE MATERIALS 3 4 19 PLATFORM TOP VIEW OF PLATFORM E G 16 406 16 406 4 102 BACK WALL ISLAND INSTALLATIONS 12 305 MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 0 TO NON COMBUSTIBLE MATERIALS LOCATION OF GAS AND ELECTRICAL SUPPLY CUT OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLA...

Page 5: ...s own 15 amp circuit breaker Locate electrical and gas supply within the shaded area shown in the Installation illustration IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Wolf sealed burner rangetops are designed to operate on natural gas at 5 12 5 mb WC water column pressure or LP propane gas at 10 25 mb WC pressure The minimum li...

Reviews: