Planning Information

30"

(762)

Sealed Burner Rangetop

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, finished rough opening
dimensions and installation specifics.

IMPORTANT NOTE:

Caution must be used in

planning the proper installation of the Wolf
sealed burner rangetop to avoid any fires or
damage to adjacent cabinetry or kitchen equip-
ment. Follow the minimum clearances estab-
lished in the finished rough opening dimensions
as shown in the Installation illustration.

The platform for the rangetop must be 

3

/

4

"

(19) thick and include a cut-out at the right rear
for gas supply and electrical connections. The
platform must be level to ensure that the
cooking surface is level.

It is recommended that you use a Wolf Pro

wall or island ventilation hood or hood liner
with the Wolf sealed burner rangetop. Refer to
the Pro Ventilation section of our website,
wolfappliance.com.

The Wolf sealed burner rangetop requires a

110/120 V AC, 50/60 Hz electrical supply to
operate the electronic ignition system. The
power supply cord is equipped with a 3-prong,
grounded plug for protection against shock
hazard. The service should have its own 15
amp circuit breaker. Locate electrical and gas
supply within the shaded area shown in the
Installation illustration.

IMPORTANT NOTE:

A ground fault circuit

interrupter (GFCI) is not recommended and may
cause interruption of operation.

Wolf sealed burner rangetops are designed

to operate on natural gas at 5" (12.5 mb) WC
(water column) pressure or LP (propane) gas at
10" (25 mb) WC pressure. The minimum line
pressure for natural gas is 7" (17.5 mb) WC and
11" (27.4 mb) WC for LP gas. The maximum
gas supply pressure to the regulator should
never exceed 14" (34.9 mb) WC; .5 psi (3.5
kPa).

If local codes permit, a certified, 3' (.9 m)

long, 

1

/

2

" or 

3

/

4

" ID flexible metal appliance

connector is recommended for connecting the
rangetop to the gas supply line.  

IMPORTANT NOTE:

A separate external gas

shut-off valve must be located near the
rangetop in an accessible location. 

Wolf sealed burner rangetops using natural

gas will operate up to an altitude of 8,000'
(2438 m) without any adjustment. Natural gas
and LP gas installations from 8,000' (2438 m)
to 11,000' (3353 m) need the high altitude
conversion kit. Contact your Wolf dealer for
details. To obtain local dealer information, 
visit the Locator section of our website, 
wolfappliance.com.

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

Summary of Contents for SRT304

Page 1: ... higher settings the lower tier continuous flame ably handles the subtleties of simmering and melting These rangetops offer you that commercial look but give you flexibility to use the ovens in other locations in the kitchen In fact the Wolf framed ovens would be a beautiful complement to these cooking instruments Let Wolf the corporate companion and kitchen soul mate of Sub Zero fuel your passion...

Page 2: ...rface burners all with simmer capabilities and automatic reignition at all settings 15 000 Btu hr 4 4 kW burners with 950 Btu hr 3 kW delivered at simmer 9 200 Btu hr 2 7 kW burner with 325 Btu hr 1 kW delivered at simmer and melt feature Certified by Star K to meet religious regulations CSA certified for US and Canada Two and five year residential warranty exclusions apply warranty information ca...

Page 3: ... kg Specifications are subject to change without notice M O D E L O P T I O N S Four Burners SRT304 Natural gas model listed for LP gas add LP to the model number V E N T I L A T I O N O P T I O N S 30 762 Pro wall hood or liner 36 914 Pro wall or island hood Refer to the Wolf Pro Ventilation section of our website wolfappliance com for additional information A C C E S S O R I E S 5 127 or 10 254 ...

Page 4: ... min 762 TO 36 max 914 TO BOTTOM OF VENTILATION HOOD 30 min 762 COUNTERTOP TO COMBUSTIBLE MATERIALS 3 4 19 PLATFORM TOP VIEW OF PLATFORM E G 16 406 16 406 4 102 BACK WALL ISLAND INSTALLATIONS 12 305 MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 0 TO NON COMBUSTIBLE MATERIALS LOCATION OF GAS AND ELECTRICAL SUPPLY CUT OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLA...

Page 5: ...s own 15 amp circuit breaker Locate electrical and gas supply within the shaded area shown in the Installation illustration IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Wolf sealed burner rangetops are designed to operate on natural gas at 5 12 5 mb WC water column pressure or LP propane gas at 10 25 mb WC pressure The minimum li...