SITE PREPARATION
Preparation
Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket and hardware.
Remove the kickplate by extracting the two mounting
screws. Refer to the illustration below.
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
The back of the anti-tip bracket must be installed 610 mm
from the front of the unit (without panels).
Use all anti-tip bracket hardware as instructed for wood or
concrete floors.
IMPORTANT NOTE:
For wood or concrete floor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE:
In some installations the subflooring or
finished floor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.
ANTI-TIP HARDWARE
1
Anti-tip bracket
12
#12 x 64 mm pan head screws
4
3
/
8
"–16 x 95 mm wedge anchors
12
#12 flat washers
4
#8–18 x 32 mm truss head screws
4
Nylon Zip-it
®
wall anchors
SCREW
Kickplate removal.
WOOD FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening,
drill pilot holes 5 mm diameter maximum in the wall studs or
wall plate. Use the #12 screws and washers to secure the
brackets. Verify the screws penetrate through the flooring
material and into wall studs or wall plate a minimum of 19
mm. Refer to the illustration and chart below.
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening,
drill pilot holes 5 mm diameter maximum in the wall studs
or wall plate. Drill 10 mm diameter holes into the concrete a
minimum of 38 mm deep. Use the #12 screws and washers
to secure the brackets to the wall, and use the
3
/
8
" wedge
anchors to secure the brackets to the floor. Verify the screws
penetrate wall studs or wall plate a minimum of 19 mm.
Refer to the illustration and chart below.
ANTI-TIP BRACKET PLACEMENT
WIDTH
A
457 mm Models
229 mm
610 mm Models
305 mm
762 mm Models
318 mm
914 mm Models
457 mm
A
A
SUBFLOORING
WOOD FLOOR
WALL PLATE
FINISHED
FLOORING
A
A
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
38 mm
min
Wood floor.
Concrete floor.
Plumbing
Installation must comply with all applicable plumbing codes.
The water supply line should be located within the shaded
area shown in the illustrations below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must be flush to the floor and not
interfere with installation of the anti-tip bracket.
An in-line filter is required for models with an ice maker or
water dispenser when water conditions have a high sedi-
ment content.
A reverse osmosis system can be used provided there
is constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply Line
1
/
4
" OD copper, braided
stainless steel or PEX tubing
Water Pressure
2.4–8.3 bar
Excess Water Line for Connection
.9 m
WATER SUPPLY LOCATION
WIDTH
A
457 mm Models
76 mm
610 mm Models
140 mm
762 mm Models
152 mm
914 mm Models
229 mm
76 mm
FRONT VIEW
FLOOR
TOP VIEW
BACK WALL
13 mm
152
mm
A
WATER
LINE
A
152
mm
RIGHT SIDE
OF OPENING
RIGHT
SIDE OF
OPENING
76 mm
FRONT VIEW
FLOOR
TOP VIEW
BACK WALL
13 mm
152
mm
A
WATER
LINE
A
152
mm
RIGHT SIDE
OF OPENING
RIGHT
SIDE OF
OPENING
Water supply location (rear).
Water supply location (bottom).