Transport / storage
STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
- 12 -
3.
TRANSPORT / STORAGE
-
Before transport, fully drain the system and seal with plugs to prevent water from escaping.
-
Pack the system in a sufficiently large and cushioned cardboard box
(preferably the original box) for transport, to prevent damage.
-
It is essential to avoid the formation of ice inside the system.
-
The system may only be stored in a temperature range of +4...+45°C.
-
Membranes must be packed in a watertight bag.
4.
MECHANICAL REQUIREMENTS
Secure both the system installation board and the pressure tank so they cannot fall over. The installation
board can be fastened to sturdy walls (concrete, masonry, wood) using the supplied screws and dowels.
For other materials, use suitable fastening equipment. The pressure tank can be positioned upright. Pre
-
vent hoses from falling or being caught by choosing suitable fastening equipment.
5.
APPLICATION LIMITS
Reverse osmosis membranes are sensitive to frost. Therefore, never allow the temperature to drop below
freezing. The system, filled pressure tank and spare membranes may only be stored in a temperature
range of +4...+45°C.