background image

1

Safety informations ........................................................................................................................... page 2

Technical features.............................................................................................................................. page 3

Before using....................................................................................................................................... page 4

Lamp  installation, replacement and setting .................................................................................... page 5

Beam angle setting ........................................................................................................................... page 6

Control panel  .................................................................................................................................... page 8

Control panel configuration and fixture management .................................................................... page 9

ENGLISH INDEX

Summary of Contents for 0305

Page 1: ...User s and operator s manual for art 0305 PROVISIONAL...

Page 2: ...page 2 Technical features page 3 Before using page 4 Lamp installation replacement and setting page 5 Beam angle setting page 6 Control panel page 8 Control panel configuration and fixture management...

Page 3: ...alls or any other type flammable surfaces 3 Maintain minimum distance to lighted objects of 5 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot close to heat so...

Page 4: ...ynchronised auto switch on off which is operated on a weekly timer weekly schedule CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 DMX CHANNELS 1 motor speed 2 pink 3...

Page 5: ...e connection cable on the spot when it is warm b This unit must be positioned as to allow its ventilation c The unit must be positioned at least 50 cm from walls or other flammable surfaces d Observe...

Page 6: ...lamp support plate pict 4 6 Remove the lamp holder D and insert the lamp into the lampholder pict 5 Do not touch the quarz bulb with fingers If this happenes clean the bulb before use with dry cloth a...

Page 7: ...on the head cover and remove it pict 5 2 Loosen the two pommels P under the dicrhoic group I pict 5a 3 Rotate clockwise of 45 the parabole up to stop it pict 6 and 6a 4 Screws the two pommels P pict 6...

Page 8: ...the four screws Q 4 Remove the wire protection U 5 Open the other three spring lock S on the three side of the dichroic unit I 6 Unscrew and remove the wire protection V 7 Disconnect the connecter Z a...

Page 9: ...s Sub menus This icon shown that is possible directly to insert the values Choosed menu change the values EXAMPLE 1 ICON EXAMPLE 2 ICON 1 2 1 2 icon UTILITY Programs Master Auto Define User O k E s c...

Page 10: ...progressive 256 levels value 0 255 RESET lamp SWITCHING OFF value 0 127 no operation 128 191 motor reset 192 239 no operation 240 250 lamp turning off 251 255 no operation ON BOARD CONTROL PANEL BASIC...

Page 11: ...er U1 1 EDIT U2 modify record preset user U2 EDIT U3 modify record preset user U3 EDIT U4 modify record preset user U4 ADVANCED LANGUAGE to choose language AUTO TST function test FIXT RESET reset item...

Page 12: ...ING OF A PRESET USER To edit any PRESET it s important that the equipment both set for working in DMX For the mode operative enter in the menu UTILITY so in the sub menu PROGRAMS The first voice sign...

Page 13: ...break of time fixed 4 Insert the week day or the combination of days which the program at hand it must to be carry out Once introduced all parameters save the program and exit with ESC The program MM...

Page 14: ...o essere soggette a variazioni senza preavviso Rev 1 800e 06 2004 Asia branch STUDIO DUE Far East LTD Unit D 29 F West Gate Tower 7 Wing Hong Street Kln Hong Kong tel 852 29542141 fax 852 23302515 Hea...

Reviews: