Studer Vista 5 M2 User Manual Download Page 7

Vista 5 M2 Digital Mixing System

TFT Meters  7

Date printed: 09.06.11

SW V4.5

 

  Surround channels come per default with a surround image view in the lower 

area, offering a spatial visualization of the surround signal. It allows spotting 

anomalities in a surround signal much faster than any other method.

 

  Alternatively, a bus assign view can be selected on any channel, giving a nice 

overview of the bus routing right below the bargraph meters. This may not be 

sensible for every channel but is useful for the ones where the bus assignment 

is changed frequently.

 

Control Bay

  The control bay TFT metering is of multiple use. The 

VIEW

 keys 

together with 

the 

ñ

 (shift) key

  allow switching between different views. All 

VIEW

 keys are 

of the momentary/latching type.

 

 The 

FOLLOW

 key displays the metering that belongs to the channel assigned 

to the desk surface. 

 

  Then, there are view keys for all different type of master channels: Aux, 

Groups, program Masters, Matrix, etc., as well as output meter views of 

multitrack and n-1/x busses. 

 

  Moreover, there are four user keys that allow displaying any choice of chan-

nels of the mixing console on the four user pages. For assignment there is a 

page on the GC’s Strip Setup window that lets assign up to 10 channels on 

the 

USER 1

 page, up to 20 channels in two rows on the 

USER 2

 page, and 

a maximum of 40 half-width channels in two rows on both the 

USER 3

 and 

USER 4

 pages. 

  

The two meter slots at the right of the control bay TFT screen, however, con-

tinuously show PFL and CR levels.

Summary of Contents for Vista 5 M2

Page 1: ...5 VISTA 5 M2 SW V4 5 DIFFERENCES AND NEW FEATURES Please insert this document at the end of chapter 10 of your Vista 5 operating instructions folder Meterbridge Installation Option 3 Mechanical 3 Electrical 4 Configuration 4 System Start 4 TFT Level Meters 5 TFT Meter Setup 8 ...

Page 2: ...Vista 5 M2 Digital Mixing System 2 TFT Meters Date printed 09 06 11 SW V4 5 ...

Page 3: ...ed since one of the meterbridge screens is provided for this purpose Remove the 6 countersunk head screws at the rear of the console marked in red in the picture below Use a 2 5 mm Allen key These screws will no more be used 32 fader console 42 fader console VGA SECONDARY LAN PRIMARY LAN GRAPHICAL CONTROLLER SCREEN VGA DVI CUSTOM PANEL GPIO COM1 RS422 COM2 RS422 DATA USB 12 24V DIN MIDI IN MIDI OU...

Page 4: ...condary Lan Port to Meterbridge Switch Meterbridge PC to Meterbridge Switch GC DVI Signal to Meterbridge Meterbridge PC Bottom View Ext DVI Input Power ON GC DVI Input Power ON GC DVI Input Ethernet Ethernet USB Power On Link to Meterbridge PC Cat5 Ethernet Connection Cat5 MADI Connection DVI Connection Power On Connection Configuration For correct operation of the TFT meters open the D950system i...

Page 5: ...ormation a lower area is configurable that enables displaying different options depending on the channel type It can bring a surround image view or what is called the history diagram of incoming or outgoing signal waveforms This shows the history of the signal and makes it easy to spot anomalies in the audio signal such as overloads or signal loss When focusing on some important channels one might...

Page 6: ...on meter on top of the meter bars both on stereo inputs as well as on stereo master channels Above the level bargraph area gain reduction meters are added Clipping is displayed by turning the white bargraph section i e the segments above the headroom threshold over to red The meter tap point can be selected from input post fader and direct output level of the corresponding channel It is possible t...

Page 7: ...ñ shift key allow switching between different views All VIEW keys are of the momentary latching type The FOLLOW key displays the metering that belongs to the channel assigned to the desk surface Then there are view keys for all different type of master channels Aux Groups program Masters Matrix etc as well as output meter views of multitrack and n 1 x busses Moreover there are four user keys that ...

Page 8: ...in the strip setup window that is a slow indication of signal activity at this channel s input Color is used to identify the channel s status A blue meter bar means that the channel has its fader open and is switched on If the meter bar is gray then the channel has a signal associated with it but either the channel fader is closed or the channel is muted off If the meter bar is red the channel cur...

Page 9: ...labeled DEF These are the history view for mono and stereo channels and the surround view for 5 1 channels When right clicking into the lower meter area the display mode of the lower part of the meter can be selected HIST for the history display BUS for bus assignment view SRND for surround view and L2 for layer 2 view Options not available for a particular channel type will be grayed out Changes ...

Page 10: ...Vista 5 M2 Digital Mixing System 10 TFT Meters Date printed 09 06 11 SW V4 5 ...