Studer Innotec SA
VarioString
User manual
55
Level
User
ref. Parameter
Factory value
User
value
Expert 14072
Combination of the events for the auxiliary contact
(AUX 1)
Any (Function OR)
Expert 14074 Activated in night mode (AUX 1)
No
Expert 14075 Delay of activation after entering night mode (AUX 1)
1 min
Expert 14076
Activation time for the auxiliary relay in night mode
(AUX 1)
1 min
Expert 14078 VarioString is OFF (AUX 1)
No
Expert 14079 Battery undervoltage (AUX 1)
No
Expert 14080 Battery overvoltage (AUX 1)
No
Expert 14081 Earth fault (AUX 1)
No
Expert 14082 PV error (48h without charge) (AUX 1)
No
Expert 14083 Overtemperature (AUX 1)
No
Expert 14084 Bulk charge phase (AUX 1)
No
Expert 14085 Absorption phase (AUX 1)
No
Expert 14086 Equalization phase (AUX 1)
No
Expert 14087 Floating (AUX 1)
No
Expert 14088 Reduced floating (AUX 1)
No
Expert 14089 Periodic absorption (AUX 1)
No
Expert 14091 Battery voltage 1 activate (AUX 1)
No
Expert 14092 Battery voltage 1 (AUX 1)
46.8 Vdc
Expert 14093 Delay 1 (AUX 1)
1 min
Expert 14094 Battery voltage 2 activate (AUX 1)
No
Expert 14095 Battery voltage 2 (AUX 1)
47.8 Vdc
Expert 14096 Delay 2 (AUX 1)
10 min
Expert 14097 Battery voltage 3 activate (AUX 1)
No
Expert 14098 Battery voltage 3 (AUX 1)
48.5 Vdc
Expert 14099 Delay 3 (AUX 1)
60 min
Expert 14100 Battery voltage to deactivate (AUX 1)
54 Vdc
Expert 14101 Delay to deactivate (AUX 1)
60 min
Expert 14102 Deactivate if battery in floating phase (AUX 1)
No
Expert 14104
Contact activated with the temperature of battery
(AUX 1)
No
Expert 14105 Contact activated over (AUX 1)
3 °C
Expert 14106 Contact deactivated below (AUX 1)
5 °C
Expert 14107
Only activated if the battery is not in bulk phase
(AUX 1)
No
Expert 14109 Contact activated with the SOC 1 of battery (AUX 1)
No
Expert 14110 Contact activated below SOC 1 (AUX 1)
50 % SOC
Expert 14111 Delay 1 (AUX 1)
12 hours
Expert 14112 Contact activated with the SOC 2 of battery (AUX 1)
No
Expert 14113 Contact activated below SOC 2 (AUX 1)
30%
Expert 14114 Delay 2 (AUX 1)
0.2 hours
Expert 14115 Contact activated with the SOC 3 of battery (AUX 1)
No
Expert 14116 Contact activated below SOC 3 (AUX 1)
20%
Expert 14117 Delay 3 (AUX 1)
0 hours
Expert 14118 Contact deactivated over SOC (AUX 1)
90 % SOC
Expert 14119 Delay to deactivate (AUX 1)
0.2 hours
Expert 14120 Deactivate if battery in floating phase (AUX 1)
No
Expert 14121 Reset all settings (AUX 1)
-
Expert 14123 Operating mode (AUX 2)
Automatic
Summary of Contents for VarioString VS-120
Page 2: ...Studer Innotec SA VarioString 2 V 2 3 User manual ...
Page 13: ...Studer Innotec SA VarioString User manual V 2 3 13 4 1 2 VarioString VS 120 ...
Page 61: ...Studer Innotec SA VarioString User manual V 2 3 61 ...
Page 62: ...Studer Innotec SA VarioString 62 V 2 3 User manual ...
Page 63: ...Studer Innotec SA VarioString User manual V 2 3 63 ...