Info. no.
Name
Unit
Description
15000
Ubat
Vdc
Battery voltage
15001
Ibat
Adc
Battery current
15002
Phas
Text
Battery cycle phase (Bulk, Absorpt., Equalize, Floating, ---, ---,
R.float., Per.abs., ---, ---, ---, ---)
15003*
conf
Text
PV type of wiring (Unknown, Independ., Series, Parallel, Error)
15004*
Upv
Vdc
PV voltage
15005*
Upv1
Vdc
PV1 voltage
15006*
Upv2
Vdc
PV2 voltage
15007*
Ipv
Adc
PV current
15008*
Ipv1
Adc
PV1 current
15009*
Ipv2
Adc
PV2 current
15010
Ppv
kW
PV power
15011*
Ppv1
kW
PV1 power
15012*
Ppv2
kW
PV2 power
15013*
Mode
Text
PV operating mode (Night, Security, OFF, Charge, ChargeV,
Charge I, ChargeP, ChargeIpv, ChargeT, ---, Ch.Ibsp)
15014*
Mod1
Text
PV1 operating mode (Night, Security, OFF, Charge, ChargeV,
Charge I, ChargeP, ChargeIpv, ChargeT, ---, Ch.Ibsp)
15015*
Mod2
Text
PV2 operating mode (Night, Security, OFF, Charge, ChargeV,
Charge I, ChargeP, ChargeIpv, ChargeT, ---, Ch.Ibsp)
15016
Cd
Ah
Production PV in (Ah) for the current day
15017
Ed
kWh
Production PV in (kWh) for the current day
15018*
Ed1
kWh
Production PV1 in (kWh) for the current day
15019*
Ed2
kWh
Production PV2 in (kWh) for the current day
15020
kWhR
kWh
Produced PV energy resettable counter
15021*
kWh1
kWh
Produced PV1 energy resettable counter
15022*
kWh2
kWh
Produced PV2 energy resettable counter
15023
MWhT
MWh
Total PV produced energy
15024*
MWh1
MWh
Total PV1 produced energy
15025*
MWh2
MWh
Total PV2 produced energy
15026
Cd-1
Ah
Production PV in (Ah) for the previous day
15027
Ed-
kWh
Production PV in (Wh) for the previous day
15028*
Ed1-
kWh
Production PV1 in (Wh) for the previous day
15029*
Ed2-
kWh
Production PV2 in (Wh) for the previous day
15030*
Sd
h
Number of irradiation hours for the current day
15031*
Sd-1
h
Number of irradiation hours for the previous day
15032
Tbat
°C
Battery temperature
15033*
Upmx
Vdc
Max PV voltage for the current day
15034*
Upm1
Vdc
Max PV1 voltage for the current day
15035*
Upm2
Vdc
Max PV2 voltage for the current day
15036*
Ibmx
Adc
Max battery current of the current day
15037*
Ppmx
kW
Max PV power for the current day
15038*
Ppm1
kW
Max PV1 power for the current day
15039*
Ppm2
kW
Max PV2 power for the current day
15040*
Ubmx
Vdc
Max battery voltage for the current day
15041*
Ubmn
Vdc
Min battery voltage for the current day
Summary of Contents for VarioString VS-120
Page 2: ...Studer Innotec SA VarioString 2 V 2 3 User manual ...
Page 13: ...Studer Innotec SA VarioString User manual V 2 3 13 4 1 2 VarioString VS 120 ...
Page 61: ...Studer Innotec SA VarioString User manual V 2 3 61 ...
Page 62: ...Studer Innotec SA VarioString 62 V 2 3 User manual ...
Page 63: ...Studer Innotec SA VarioString User manual V 2 3 63 ...