background image

STUDER K + I 
Kommunikation und Informatik

 

 

STUDER

 

®

 

 

 

 

 

 

 

EX-E99-TK.doc / 17 / Tog / 31.08.2006 

Page 5 of 8

 

STUDER K + I 

Kommuni Informatik 
Tavelweg 2 
CH-3074  Muri BE 

Phone 
Fax 
Mobile 

031 959 11 11 
031 959 11 44 
079 302 11 11 

 
Web:    www.studercom.ch

 

Email: [email protected] 

PC no. 30-7032-0

MWSt. no. 367 246

Gewerbekasse in Bern

 

2. Customised EXICALL Programming (software version V02.22) 

EXICALL connection:             

‰

 Exchange line     

‰

 internal    Tel. no.  _____ /_____________  

Name ___________________ Company __________________   Tel. no.  ___________________

 

 

1.  sub-menu 

2.  sub-menu 

3.  sub-menu 

 

selection (status) 

default progr 

customer progr. 

1: Programming 

1: Password 

  

(4 digits) 

1234 

 

  

2: 

Remote 

  

1: 

Yes 

 

 

Main Menu 

 

 

(remote programming) 

2: No 

 

 

1:  Display 

 

3:  Remote control password 

1: 

Yes 

 

 

2:  Change  

 

(for commands *1 to *9) 

2: No 

 

3:  Test 

 

4:  Ext. C/A. contact 

 

 

1: 

Ext. call key 

 

  1  Dial 1

st

 number 

 

 

(floating contact K2) 

2: Acknowl. 

contact 

 

 

  2  Dial 2

nd

 number 

 

 

 

  

3: 

Day/night 

 

 

  3  Hardware test 

 5: 

Answer 

 

 

1: 

Yes (after 10 rings) 

 

  4  Software version 

 

 

(incoming call) 

2: Yes 

(immediately)   

 

  5  Language sel. 

 

 

(2: and 3: no remote programming) 

3: 

No 

 

 

2: Language 

sel. 

1: LCD 

(display) 

  

1: 

German 

 

 

 

 

 

  

2: 

French 

 

 

 

 

 

 

  

3: 

Italian 

 

 

 

 

 

 

  

4: 

English 

 

 

 

 

 

 

  

5: 

rotating 

 

 

  

2: 

Synth. 

voice 

  

1: 

German 

 

 

 

 

 

  

2: 

French 

 

 

 

 

 

 

  

3: 

Italian 

 

 

 

 

 

 

  

4: 

English 

 

 

3: Identification 

1: ID 

number 

  

(max. 16 digits / #) 

 

  

2: 

Output 

type 

  

1: 

Synth. 

voice 

 

 

 

 

 

 

  

2: 

DTMF dialling 

 

 

 

 

 

 

  

3: 

No 

ident. 

 

4: Dialling 

mode 

 

 

  

1: 

Pulse 

dialling 

 

 

 

 

 

 

  

2: 

DTMF dialling 

 

5: Ext. 

disabling 

 

 

  

1: 

Active 

 

 

 

 

 

 

  

2: 

Not 

active 

 

6:  Call set up 

 

 

  

1: 

Immediate 

 

 

(After selections  

 

EXICALL No. 

  

2: 

0.5 

 

 

 

2 - 8 key must be 

 

 

  

3: 

 

 

 

held down long 

 

Date 

  

4: 

1.5 

 

 

 

enough for the call 

 

 

  

5: 

 

 

 

to be activated) 

 

Signature 

  

6: 

2.5 

 

 

 

 

 

 

  

7: 

 

 

 

 

 

 

  

8: 

3.5 

 

 

 

 

 

 

  

9: 

Confirmation 

(2x) 

 

 

7: Preset. 

numbers 

1: 1

st

 preset no. 

1: Number 

(max. 16 digits) 

111 

 

 

 

 

(Day, contact K2 

2: Code 

1: Yes (wait) 

 

 

 

 

 

open) 

 

 

2: No 

 

 

 

 

 

3: Tax 

impulses 

1: Yes(wait) 

 

 

 

 

 

 

 

 

2: No 

 

  

2: 

2

nd

 preset. no. 

1: Number 

(max. 16 digits)  

(0) 111 

 

 

 

 

(Night, contact K2 

2: Code 

1: Yes (wait) 

 

 

 

 

closed) 

 

 

2: No 

 

 

 

 

 

 

3: Charge 

pulses 1: 

Yes (wait) 

 

 

 

 

 

 

 

 

2: No 

 

  

3: 

Access 

code 

 

 

X 0 (for  example) 

0  

  

4: 

Dial 

2

nd

 number 

 

 

1: No 

 

 

 

 

 

 

 

 

2: 1

st

 no. no reply  

 

 

 

 

 

 

 

 

3: 1

st

 no. engaged 

 

 

 

 

 

 

 

 

4: 1

st

 no. eng./no reply   X 

 

 * 

751 corresponds to  5: 

Call 

setup 

 

 

1: 

Line seizure only* 

 

 

 

lifting receiver w/o dial.   

 

2: 

Seize line and dial 

X X 

(default) 

8: Volume 

1: Loudspeaker 

 

 

Step: 1 ... 4 

4  

  

2: 

Ringer 

 

 

Step: 1 ... 4 

4 (1 = off) 

 

  

3: 

Melody 

 

 

Step: 1 ... 4 

4  

 

 

4:  Ambient noise level   

 

1: Normal 

 

 

 

 

 

 

 

2: High 

 

 

 

 

5:  Line signal level 

 

 

1: Normal 

 

 

 

 

 

 

 

2: Poor 

 

 

9: Call 

time 

(limit:) 

 

 

01 ... 15 (minutes) 

03 min 

 

Summary of Contents for EXICALL NIT 960

Page 1: ...hange Programming can be performed only with the exchange line and power supply connected See pages 5 and 6 for instructions New Remote control standard from s n 1000 onwards 10 commands possible during the call additional contact K3 plus remote hang up 7 pulse lengths from 2 8 seconds 1 pulse held until end of call 1 test acknowledgement contact 1 remote call termination New Seizure relay option ...

Page 2: ...h PC no 30 7032 0 MWSt no 367 246 Gewerbekasse in Bern Table of Contents Chapter Page 1 EXICALL Technical Data 3 2 Customised EXICALL Programming 5 3 EXICALL Local Programming 6 4 EXICALL Remote Programming 6 5 Additional Functions and Modifications for software version V02 22 7 6 Remote Control terminal assignment and function description 7 7 Seizure Relay Option function description 8 8 Day Nigh...

Page 3: ...etup initiated at 11V 60V DC or 11V 42V AC Environmental conditions Temperature 0 50 C Humidity 20 70 rel humidity Casing Dimensions 80 x 268 x 41mm B x H x D Weight Approx 750g Approvals Switzerland BAKOM no 94 0759 T N Germany Netherlands Telephone line Switzerland Type a b analogue Equivalent circuit for a b impedance 820 Ohm 220 Ohm 115 nF a b Dialling mode Pulse or DTMF touch tone External li...

Page 4: ...ine Using tone dial telephone and spoken prompts G F I E Security protection Password Call set up Preset numbers 2 Max digits per telephone no 17 1 PBX access code digit 16 digit telephone no Setup procedure Selectable line seizure dial 1st preset number line seizure PBX code dial 1st preset number line seizure only Initiate call setup using call button Selectable immediate 0 5 3 5 seconds delay p...

Page 5: ... No 2 Language sel 1 LCD display 1 German X 2 French 3 Italian 4 English 5 rotating 2 Synth voice 1 German X 2 French 3 Italian 4 English 3 Identification 1 ID number X max 16 digits 0 2 Output type 1 Synth voice 2 DTMF dialling 3 No ident X 4 Dialling mode 1 Pulse dialling 2 DTMF dialling X 5 Ext disabling 1 Active 2 Not active X 6 Call set up 1 Immediate X After selections EXICALL No 2 0 5 s 2 8...

Page 6: ... Enter menus select 1 Escape stop ESC 1 Select Browse 7 delete line DEL Attention All the parameters can be changed only in the status enter column with the exception of language selection for programming which must be done after entering the password Programming is carried out according to chapter 2 Customised EXICALL Programming page 5 4 EXICALL Remote Programming 1 Connect EXICALL to an exchang...

Page 7: ...set to 1 off in programming item no 282 Attention If incoming calls are disabled using the method described above remote programming of EXICALL is no longer possible 6 Remote Control Option 6 1 Remote control operation Remote control by the called party is possible by issuing the following commands during a call only possible from a touch tone dial telephone Cmd Contact K3 closes Password Cmd Cont...

Page 8: ...ssignment relay a b 12V AC or DAY NIGHT switch open day 1st number 7 Seizure Relay Option A seizure relay is available as an additional component inserted in series with the a b connection The floating output contact K4 is closed from the time the key is pressed until the end of the call 8 Day Night Switch Option EXICALL can now be programmed via menu item no 143 so that the ext C A contact K2 is ...

Reviews: