Troubleshooting
8
Troubleshooting
If faults occur which are not speci
¿
ed in the following table or
cannot be traced back to the speci
¿
ed causes, please consult
the manufacturer.
Possible faults are identi
¿
ed by a fault number in the table
below. This number identi
¿
es the respective cause and rem-
edy in the troubleshooting list.
Fault
Number
Pump not pumping
1
Pumping rate insuf
¿
cient
2
Pumping rate excessive
3
Pumping pressure insuf
¿
cient
4
Pumping pressure excessive
5
Pump running roughly
6
Pump leaks
7
Excessive motor power uptake
8
Tab. 5
Fault/number assignment
Fault number
1
2
3
4
5
6
7
8
Cause
Remedy
X
–
–
–
–
–
–
–
Pressure pipe closed by
¿
tting
Open the
¿
tting.
X
X
–
X
–
X
–
–
Pump or suction strainer blocked or
encrusted
Clean intake/suction pipe, pump or
suction strainer.
X
–
–
–
–
–
–
–
Transport and sealing cover still in place
Remove the transport and sealing cover.
— X
— X
— X
— — Back pressure of the system is too high,
pump selected is too small.
Consult the manufacturer.
–
X
–
X
–
X
–
–
Suction head too large: NPSH
pump
is larger
than NPSH
system
Increase pump inlet pressure.
Consult the manufacturer.
X
–
–
–
–
X
–
–
Intake/suction pipe and pump not correctly
vented or not completely
¿
lled
Completely
¿
ll and vent pump and/or
pipe.
X
X
–
X
–
X
–
–
Air is sucked in
Check the
¿
lling level of the container.
X
X
–
X
–
X
–
–
Proportion of gas too high: pump is
cavitating
Consult the manufacturer.
–
X
–
X
–
X
–
–
Temperature of
À
uid is too high: pump is
cavitating
Increase pump inlet pressure.
Lower temperature.
Contact the manufacturer.
–
X
–
X
–
–
–
X
Viscosity or speci
¿
c gravity of the pumped
liquid outside the range speci
¿
ed for the
pump
Consult the manufacturer.
X
X
–
X
–
–
–
–
Geodetic differential head and/or pipe
À
ow
resistances too high
Remove sediments from the pump
and/or pressure pipe.
Install a larger impeller and consult the
manufacturer.
–
X
–
–
X
X
–
–
Pressure-side
¿
tting not opened wide
enough
Open the pressure-side
¿
tting.
X
X
–
–
X
X
–
–
Pressure pipe blocked
Clean the pressure pipe.
301 356
BA-2018.01.25 EN
ETLB-S, ETLB-ST
23