Fuses
The following fuse size should be used with the appropriate pump:
- 11 -
Wiring of connection unit
WARNING: This appliance must be earthed.
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead of this appliance may not correspond with
the coloured markings identifying the terminals in your connection unit proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
connection unit which is marked with the letter E or by the earth symbol: or coloured
green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with
the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
Wiring Diagrams
The supply cord and internal wiring within the terminal box are routed
and secured to ensure compliance with the electrical standard EN60335-1.
It is essential that any disturbance of this internal wiring is avoided and the
factory routing and securing of all internal wiring is always maintained.
Monsoon Extra N1.3 bar Single
Fig. 12
Monsoon Extra N2.4, N2.9 & N3.7 bar Single
Fig. 13
Model
Fuse Size (Amps)
Monsoon Extra N1.3 bar
5
All other models
13
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
LIN
K WIRE
BROWN
BLA
CK
M
A
N
S2 S3 S3 S2
FLOWSWITCH
REED (S3)
S1
S1
PRESSURE
SWITCH (S1)
BLUE
BLUE
BROWN
N
L
E
GREEN YELLOW
230 VAC/1PH/50Hz
SUPPLY
N
L
L
S1
S2
S3
S3
S2
S1
N
N
A
M
L
N
E
BR
OW
N
BLUE
GREEN/YE
LLO
W
PRESSURE
SWITCH
FLOWSWITCH
REED
BROWN
BLUE
GREEN/YELLOW
CAPACITOR
MOTOR
BLA
CK
BLA
CK
BR
OW
N
WHITE
BLU
E
230 VAC/1PH/50Hz SUPPLY