Install the Mainsboost Monobloc between the stopcock and the rest of the system using the compression fittings and
adaptors supplied. Refer to the chart below as a guide.
Note:
Do not
forget if a water softener is to be installed this has to be included in this pipe run, and additional space
must be allocated for this.
Do not
fit smaller pipework than the Mainsboost Monobloc accepts as this will impair performance.
Do not
fit the Mainsboost Monobloc upside down. Only fit in the orientations shown in figure 2.
Ensure the Monobloc and connecting pipework are adequately supported via the use of suitable pipe clips.
MAINSBOOST
Installation, Operation & Maintenance Instructions
MAINSBOOST MONOBLOC 22MM/28MM C/W GAUGES
MAINSBOOST MONOBLOC 22MM/28MM ULK VARIANTS
PRODUCT DESCRIPTION
Mainsboost Monobloc 22mm/28mm c/w gauges ensures mains fed systems comply with water regulations, it will ensure
backflow prevention and regulate the pressure from the mains to a system.
CHECKLIST
* Items 3 and 4 are only supplied with ULK variants.
Your product may vary slightly from the illustration above.
INSTALLATION
Step 1:
Pipe
Size
Minimum pipe length required to install the
Mainsboost Monobloc
22 mm
203 mm
28 mm
203 mm
Fig. 2 Minimum pipe length
203 mm
203 mm
Fig. 1 Monobloc 22/28mm
1
5
2
3
Item Description
Qty
1
Monobloc unit
1
2
¼ “ BSP Pressure gauge
2
3
Lever isolating ball valve*
1
4
Mainsboost vessel connector
fitting*
1
5
22/28mm compression adaptor
2
4