Step 2:

Remove the grey gauge ports from the side of the Monobloc that is to face away from the wall. Fit the supplied gauges on to 

the Monobloc using PTFE tape or suitable sealant. The gauges will show the unregulated mains pressure and then the regulated 

system pressure.

Step 3:

If installing the Mainsboost Monobloc as part of a ULK kit the listed components must be installed in the correct order as shown 

in the schematic drawing below to ensure safe and satisfactory system operation.

Note: It is good practice to install a drain port between the vessel and the isolating valve to allow the vessel to be drained if 

required.

MAINTENANCE

To maintain the Mainsboost Monobloc ULK, isolate the incoming mains supply, remove the strainer cap and drain fitting as 

shown, remove any built up debrise in the strainer and replace the caps ensuring they are water tight.

Open the mains stockcock to allow supply to resume.

Fig. 3 Monobloc 22/28mm Installation

3

2

1

Inlet
Outlet

To Pump (optional)

Item Description

1

Monobloc unit

2

¼ “ BSP Pressure gauge

3

Lever isolating ball valve

4

Mainsboost vessel connector fitting

4 (under vessel)

Fig. 4 Strainer cap and drain fittings

Strainer cap

Drain fitting