PRODUCT DESCRIPTION

Electric motor driven peripheral pump with bypass, complete with an automatic control 
system consisting of flow switch and electronic control.

APPLICATION

The Flomate is a mains booster pump with an automatic control system for domestic 
use, designed to assist the pressure from the mains supply, where the mains pressure is 
insufficient.  This unit requires a minimum unassisted supply flow of 0.6 l/min to operate.
The pump is limited to producing a maximum flow of not greater than 12 l/min, and a 
maximum pressure of 3.0 bar.
When the flow/pressure from the rising main exceeds the pump output, the 

patented 

applied for integral bypass will direct the water into the system as normal.

The Flomate mains booster is a patent granted design.

Please note the following warning signs.

Warning of possible electrical hazard.

 

Possible danger to personnel or important installation requirement.

 

All the safety and operating instructions in this booklet must be  

 

 followed. 

 

The pump must not be used for any other application without the    

 

written consent of Stuart Turner Limited.

 

The pump must be installed by a qualified person.

 

The pump is not suitable for heavy commercial/industrial    

 

 applications.

 

The installation must comply with the latest Building Regulations,   

 

Wiring Regulations (BS 7671) and Water Supply Regulations (see    

 notes).

 

This appliance can be used by children aged from 8 years and  

 

 

above and persons with reduced physical, sensory or mental  

 

 

capabilities or lack of experience and knowledge if they have been  

 

given supervision or instruction concerning use of the appliance    

 

in a safe way and understand the hazards involved.  Children shall   

 

not play with the appliance.  Cleaning and user maintenance shall   

 

not be made by children without supervision.

 

Children should be supervised to ensure that they do not play with  

 the 

appliance.

Notes

 

This product must be installed in accordance with the current  

 

 

Water Supply (Water Fittings) Regulations.

 

Under no account should the internal flow restrictor be removed,    

 

or replaced with an alternative design.

Summary of Contents for Flomate Mains Boost 46574

Page 1: ...t Pump Installation Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee maintenance and safety information CE compliant product PATENT APPR...

Page 2: ...erating instructions in this booklet must be followed The pump must not be used for any other application without the written consent of Stuart Turner Limited The pump must be installed by a qualified...

Page 3: ...uct provides long trouble free service Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty STORAGE If this product is not to be insta...

Page 4: ...m the picture above A Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hours of receipt A...

Page 5: ...flux damage will void any warranty 1 15 Pipework design Care should be taken in the design of pipework runs to minimize the risk of air locks e g use drawn bends rather than 90o bends 1 16 DO NOT intr...

Page 6: ...casing can become very hot under normal operating conditions Care must be taken to ensure it cannot be touched during operation 2 15 Water retention Site the pump in a location where in the unlikely...

Page 7: ...possibility of exceeding 6 bar separate inlet pressure control must be fitted b It is advisable to fit a bypass pipe and isolating valves This will allow removal of the pump for maintenance and servic...

Page 8: ...onnection unit should be mounted in an easily accessible position and should be labelled if confusion is possible to allow easy identification of the flomate isolating switch 3 17 Earthing This applia...

Page 9: ...ectrical standard EN 60335 1 Do not disturb the internal wiring or factory routing and securing of all internal wiring Model Fuse Size AMPS All Models 5 3 21 Fuse Fig 4 MAIN WINDING THERMOTRIP CAPACIT...

Page 10: ...tem is now operating correctly d Carefully check pump and pipework for leaks whilst pump running and stationary before leaving the installation unattended 4 13 For Further Technical Support Phone the...

Page 11: ...protection Performance Maximum head closed valve 3 2 bar Maximum flow 12 l min Maximum working pressure 600 kPa 6 bar Maximum ambient air temperature 40 o C Min Max water temperature Min 4 o C Max 35...

Page 12: ...ecification see Technical Section Pump starts when outlets are off or Pump cycles hunts on off frequently Leak in system Check tap washers w c valve washers pipe joints Pump runs on when all terminal...

Page 13: ...ot start then slowly move the magnet up and down to a position that exceeds the extent of the reed clamp The pump should instantaneously start at some point during this extent of movement If this does...

Page 14: ...rmal wear and tear and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term p...

Page 15: ...co uk and complete a short form which will enable visitors to find your contact details on our web site installer finder Alternatively use your smartphone to scan this QR code and go straight to the f...

Page 16: ...IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STU...

Reviews: