Flow Switch Circuit Test:

 

1.  First confirm visually that the flow switch reed clamp has not been dislodged  

 

 

during handling or installation.  The clamp must be fully located within its flow  

 

 

switch body groove as shown.

 

2.  To carry out the following test you will need to obtain a magnet, a typical  

 

 

 

fridge magnet is suitable.

 

3.  Ensure the power supply is switched on.

 

4.  Position the magnet directly in front of the reed clamp as shown.  If pump  

 

 

 

does not start, then slowly move the magnet up and down to a position  

 

 

 

that exceeds the extent of the reed clamp.  The pump should instantaneously  

 

 

start at some point during this extent of movement.  If this does not happen,   

 

 

this indicates a possible fault with the reed switch or the P.C.B which is  

 

 

 

located within the terminal box.  These should be checked electrically.   

 

 

 

Consult Stuart Turner for further instructions.

7.12 

Environment Protection:

  Your appliance contains valuable materials which    

 

can be recovered or recycled.

 

At the end of the products’ useful life, please leave it at an appropriate local civic  

 

waste collection point. 

Fig. 5

Groove

Body

Reed Clamp

Magnet

Summary of Contents for Flomate Mains Boost 46574

Page 1: ...t Pump Installation Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee maintenance and safety information CE compliant product PATENT APPR...

Page 2: ...erating instructions in this booklet must be followed The pump must not be used for any other application without the written consent of Stuart Turner Limited The pump must be installed by a qualified...

Page 3: ...uct provides long trouble free service Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty STORAGE If this product is not to be insta...

Page 4: ...m the picture above A Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hours of receipt A...

Page 5: ...flux damage will void any warranty 1 15 Pipework design Care should be taken in the design of pipework runs to minimize the risk of air locks e g use drawn bends rather than 90o bends 1 16 DO NOT intr...

Page 6: ...casing can become very hot under normal operating conditions Care must be taken to ensure it cannot be touched during operation 2 15 Water retention Site the pump in a location where in the unlikely...

Page 7: ...possibility of exceeding 6 bar separate inlet pressure control must be fitted b It is advisable to fit a bypass pipe and isolating valves This will allow removal of the pump for maintenance and servic...

Page 8: ...onnection unit should be mounted in an easily accessible position and should be labelled if confusion is possible to allow easy identification of the flomate isolating switch 3 17 Earthing This applia...

Page 9: ...ectrical standard EN 60335 1 Do not disturb the internal wiring or factory routing and securing of all internal wiring Model Fuse Size AMPS All Models 5 3 21 Fuse Fig 4 MAIN WINDING THERMOTRIP CAPACIT...

Page 10: ...tem is now operating correctly d Carefully check pump and pipework for leaks whilst pump running and stationary before leaving the installation unattended 4 13 For Further Technical Support Phone the...

Page 11: ...protection Performance Maximum head closed valve 3 2 bar Maximum flow 12 l min Maximum working pressure 600 kPa 6 bar Maximum ambient air temperature 40 o C Min Max water temperature Min 4 o C Max 35...

Page 12: ...ecification see Technical Section Pump starts when outlets are off or Pump cycles hunts on off frequently Leak in system Check tap washers w c valve washers pipe joints Pump runs on when all terminal...

Page 13: ...ot start then slowly move the magnet up and down to a position that exceeds the extent of the reed clamp The pump should instantaneously start at some point during this extent of movement If this does...

Page 14: ...rmal wear and tear and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term p...

Page 15: ...co uk and complete a short form which will enable visitors to find your contact details on our web site installer finder Alternatively use your smartphone to scan this QR code and go straight to the f...

Page 16: ...IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STU...

Reviews: