5  TECHNICAL SPECIFICATION

Stuart Turner reserve the right to amend the specification in line with its policy of 
continuous development of its products.

 

*Note:  The maximum pressure that can be applied to the pump under any  

 

 

 

installation conditions.

 

**Note:  A stored water temperature of 60

o

C is considered sufficient to meet all    

 

 

normal requirements and will minimise deposition of scale in hard water  

  

areas.

 

*** With footvalve fitted.

 

Although these pumps are self priming we recommend a footvalve/strainer is    

 

used if a suction lift is required.

5.11 

Noise:

  The equivalent continuous A-weighted sound pressure level at a  

 

 

distance of 1 metre from the pump does not exceed 70 dB(A).

Pump Model

CH4-30

50 Hz

46553

CH4-40

50 Hz

46554

CH4-50

50 Hz

46555

CH4-60

50 Hz

46556

General

Guarantee

2 years

WRAS approval

1601035

Features

Pump type

Centrifugal

Mechanical seal

EPDM / Carbon / Ceramic

Materials

Pump body

Brass / stainless steel

Impeller

Stainless steel

Performance

Maximum head (closed valve)

25 metres

36 metres

50 metres

62 metres

Performance @ 50 l/min

22 metres

34 metres

46 metres

56 metres

Performance @ 100 l/min

13 metres

22 metres

34 metres

44 metres

Maximum flow

140 l/min

160 l/min

Minimum static inlet pressure

0.05 bar (0.5 metres)

Maximum static inlet pressure

1.0 bar (10 metres)

Maximum working pressure*

600 kPa (6 bar)

900 kPa (9 bar)

Max. ambient air temperature (Continuous)

40 

o

C

Max. ambient air temperature (Intermittent)

50 

o

C

Min / Max water temperature**

Min 4 

o

C / Max 65 

o

C

Maximum Suction Lift***

5 metres

Connections

Pump connections

G 1¼ female (inlet), G1 female (outlet)

Motor

Type

Induction, auto-reset thermal trip

Duty rating

Continuous (S1)

Electrical

Power supply / phase / frequency

230 V a.c. / 1 / 50 Hz

Current (full load)

3.8 Amps

5.3 Amps

7.4 Amps

8.8 Amps

Power consumption

850 Watts

1182 Watts

1648 Watts

1969 Watts

Fuse rating

13 Amps

Power cable (pre-wired)

0.75 metres

Physical

Enclosure protection

IPX5

Length

360 mm

384 mm

431 mm

456 mm

Width

155 mm

187 mm

Height (excluding hoses)

190 mm

210 mm

Weight (including fittings)

11.1 Kg

11.6 Kg

16.8 Kg

19.3 Kg

Summary of Contents for CH4-30

Page 1: ...nt guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products suitable for 230 1 50 supply CE compliant product Mu...

Page 2: ...ensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their safety z z Children must n...

Page 3: ...vary slightly from the picture above Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hour...

Page 4: ...not exceed 40 o C continuous or 50 o C intermittent 1 16 DO NOT fit a pump if the hot water is heated via a method whereby the water temperature cannot be controlled such as solar or solid fuel you m...

Page 5: ...ration 2 15 Water retention Site the pump in a location where in the unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 2 16 Pump...

Page 6: ...connected to the fixed wiring of the mains supply using the factory fitted supply cord via a dedicated double pole switched fused spur off the ring main 3 17 Wiring of connection unit WARNING This ap...

Page 7: ...d available from Stuart Turner or one of its approved repairers 3 22 Cable Gland Fitting Instructions To enable correct assembly of the cable gland the O ring Fig 5 item 1 must be placed over the cabl...

Page 8: ...ance pipework use 28 mm dia 22 mm can be used but will result in reduced pump performance 4 12 Isolating valves Separate isolating valves non restrictive must be fitted to allow easy pump service 4 13...

Page 9: ...Stainless steel Performance Maximum head closed valve 25 metres 36 metres 50 metres 62 metres Performance 50 l min 22 metres 34 metres 46 metres 56 metres Performance 100 l min 13 metres 22 metres 34...

Page 10: ...urner Internal motor thermotrip activated Wait for thermotrip to auto reset and check that duty point and run time is within specification see technical specification Reduced intermittent flow Incorre...

Page 11: ...e value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim such as proof of purchase or the pump ser...

Page 12: ...BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 1999 519 EC BS EN 62233 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTO...

Reviews: