- 6 -

3  ELECTRICAL INSTALLATION / EARTHING

3.11

 Regulations:

 The electrical installation must be carried out in  

 

 

 

accordance with the current local regulations by a qualified person.

3.12

 Safety:

 In the interests of electrical safety a 30 mA residual current    

 

 

device (

R.C.D. not supplied

) should be installed in the supply circuit.   

 

 

This may be part of a consumer unit or a separate unit.

3.13  Before starting work on the electrical supply ensure power supply is   
 isolated.
3.14

  DO NOT

 allow the supply cord to contact hot surfaces, including the    

 

 

motor shell, pump body or pipework.  The cord should be safely routed  

 

 

and secured by cable clips.

3.15

 Earthing:

 This appliance must be earthed via the supply cord, which must be    

 

correctly connected to the earth point located in the terminal box.

3.16

 Connections:

 The pump must be permanently connected to the fixed wiring of   

 

the mains supply using the factory fitted supply cord, via a dedicated double  

 

 

pole switched fused spur off the ring main.

3.17 

Wiring of connection unit:

WARNING: This appliance must be earthed.

 

The wires in the mains lead are coloured in accordance with the following code:  

 

       Green and Yellow:  Earth 

  Blue:  Neutral           Brown:  Live

 

As the colours of the wires in the mains lead of this appliance may not    

 

 

correspond with the coloured markings identifying the terminals in your  

 

 

connection unit proceed as follows:

 

Green and yellow coloured wire must be connected to the terminal in the  

 

 

connection unit marked with the letter E or by the earth symbol: 

 or coloured   

 

green or green and yellow.

 

Blue coloured wired must be connected to the terminal marked with the letter N   

 

or coloured black.

 

Brown coloured wire must be connected to the terminal marked with the letter L  

 

or coloured red.

3.18 

Wiring diagram:

230 
VAC/1PH/5

0Hz 
SU

PP

LY

L       N

                      E

BROWN

BLUE

GREEN/YELLOW

RED

BLACK

CAPAC

ITO

R

MOT
OR

RED

YE

LL

OW

Fig. 4

Summary of Contents for CH4-30

Page 1: ...nt guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products suitable for 230 1 50 supply CE compliant product Mu...

Page 2: ...ensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their safety z z Children must n...

Page 3: ...vary slightly from the picture above Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hour...

Page 4: ...not exceed 40 o C continuous or 50 o C intermittent 1 16 DO NOT fit a pump if the hot water is heated via a method whereby the water temperature cannot be controlled such as solar or solid fuel you m...

Page 5: ...ration 2 15 Water retention Site the pump in a location where in the unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 2 16 Pump...

Page 6: ...connected to the fixed wiring of the mains supply using the factory fitted supply cord via a dedicated double pole switched fused spur off the ring main 3 17 Wiring of connection unit WARNING This ap...

Page 7: ...d available from Stuart Turner or one of its approved repairers 3 22 Cable Gland Fitting Instructions To enable correct assembly of the cable gland the O ring Fig 5 item 1 must be placed over the cabl...

Page 8: ...ance pipework use 28 mm dia 22 mm can be used but will result in reduced pump performance 4 12 Isolating valves Separate isolating valves non restrictive must be fitted to allow easy pump service 4 13...

Page 9: ...Stainless steel Performance Maximum head closed valve 25 metres 36 metres 50 metres 62 metres Performance 50 l min 22 metres 34 metres 46 metres 56 metres Performance 100 l min 13 metres 22 metres 34...

Page 10: ...urner Internal motor thermotrip activated Wait for thermotrip to auto reset and check that duty point and run time is within specification see technical specification Reduced intermittent flow Incorre...

Page 11: ...e value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim such as proof of purchase or the pump ser...

Page 12: ...BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 1999 519 EC BS EN 62233 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTO...

Reviews: