Stuart Turner CH4-30 Installation, Operation & Maintenance Installation, Operation & Maintenance Instructions Download Page 2

- 2 -

Cont ...

PRODUCT DESCRIPTION

Electric motor driven centrifugal pump.

APPLICATION

These self priming centrifugal pumps are designed to pump clean fresh water and can be 
used for pressure boosting, fluid transfer and distribution.

Inlet pressures to the pump and ambient temperatures must not exceed the 
values given in the technical specifications.

 

z

This pump set must not be used for any other  

 

  application without the written consent of Stuart    
  Turner Limited.

 

z

Do not connect this pump to the mains water  

 

 supply.

 

z

The use of this product requires experience with    

  and knowledge of the product. 
  Persons with reduced physical, sensory or mental  
  capabilities must not use this product, unless they  
  are under supervision or have been instructed in    
  the use of the product by a person responsible for  
  their safety.

 

z

Children must not use or play with this product.

Please read installation details carefully as they are intended to ensure this 
product provides long, trouble free service.  Failure to install the unit in 
accordance with the installation instructions will lead to invalidation of the 
warranty.

STORAGE

If this product is not to be installed immediately on receipt, ensure that it is stored in a dry, 
frost and vibration free location in its original packaging.

CONTENTS 

Page

Checklist  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Important Facts - read before commencing installation    . . . . . . . . . . . . . . . . . . . 4
Location   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Plumbing    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Technical Specification 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Trouble Shooting    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Guarantee  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Summary of Contents for CH4-30

Page 1: ...nt guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products suitable for 230 1 50 supply CE compliant product Mu...

Page 2: ...ensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their safety z z Children must n...

Page 3: ...vary slightly from the picture above Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hour...

Page 4: ...not exceed 40 o C continuous or 50 o C intermittent 1 16 DO NOT fit a pump if the hot water is heated via a method whereby the water temperature cannot be controlled such as solar or solid fuel you m...

Page 5: ...ration 2 15 Water retention Site the pump in a location where in the unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 2 16 Pump...

Page 6: ...connected to the fixed wiring of the mains supply using the factory fitted supply cord via a dedicated double pole switched fused spur off the ring main 3 17 Wiring of connection unit WARNING This ap...

Page 7: ...d available from Stuart Turner or one of its approved repairers 3 22 Cable Gland Fitting Instructions To enable correct assembly of the cable gland the O ring Fig 5 item 1 must be placed over the cabl...

Page 8: ...ance pipework use 28 mm dia 22 mm can be used but will result in reduced pump performance 4 12 Isolating valves Separate isolating valves non restrictive must be fitted to allow easy pump service 4 13...

Page 9: ...Stainless steel Performance Maximum head closed valve 25 metres 36 metres 50 metres 62 metres Performance 50 l min 22 metres 34 metres 46 metres 56 metres Performance 100 l min 13 metres 22 metres 34...

Page 10: ...urner Internal motor thermotrip activated Wait for thermotrip to auto reset and check that duty point and run time is within specification see technical specification Reduced intermittent flow Incorre...

Page 11: ...e value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim such as proof of purchase or the pump ser...

Page 12: ...BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 1999 519 EC BS EN 62233 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTO...