Introduction
9
SAFETY TIPS AND GUIDELINES (ZOOM
r
OPTION)
In addition to the previous warnings and cautions, all of the following warnings and cautions apply to units
equipped with the Zoom
option.
WARNING
The 3002 Patient Transport Frame is intended for use by trained hospital personnel only. Failure to prop-
erly train personnel could result in injury.
USE CAUTION while maneuvering the unit with the drive wheel activated. Always ensure there are no
obstacles near the unit while the drive wheel is activated. Injury to the patient, user or bystanders or dam-
age to the frame or surrounding equipment could occur if the unit collides with an obstacle.
Use caution when transporting the unit down halls, through doors, in and out of elevators, etc. Damage
to the siderails or other parts of the unit could occur if the unit comes in contact with walls or door frames.
Put the drive wheel in the neutral position and release the brakes before pushing the unit manually. Do
not attempt to push the unit manually with the drive wheel engaged. The unit will be difficult to push and
injury could result.
If unanticipated motion occurs, unplug the power cord from the wall socket, push the battery power on/off
switch to the ”OFF” position (the LED will not be illuminated) and actuate the drive wheel pedal to the
neutral position.
The power save mode is activated after one hour on battery power with no motion release switch activa-
tion. Functions including Bed Exit, scale and motion will cease to operate when the unit enters the power
save mode. Injury to the patient could occur if proper patient monitoring protocol is not observed.
Always unplug the power cord and push the battery power on/off switch to the “OFF” position before ser-
vice or cleaning. When working under the frame, always place blocks under the litter frame to prevent
injury in case the Bed Down switch is accidently activated.
Due to the weight the battery adds to the bed (approximately 50 pounds), additional force is required to
move the bed. Caution should be used when transporting this bed. Additional assistance should be used
when necessary. Failure to use caution while transporting this bed may result in injury to the user.
Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known
to the State of California to cause cancer and birth defects or other reproductive harm.
Wash hands after
handling.
Do not modify the 3002 Patient Transport Frame. Modifying the unit can cause unpredictable operation
resulting in injury to the patient or operator. Modifying the unit will also void its warranty.
CAUTION
To avoid damage while transporting the bed, verify the I.V. pole is at a low enough height to allow it to
safely pass through door openings and under light fixtures.
The battery tray assembly weighs 50 pounds. Take care when removing the two hex head screws secur-
ing it to the base frame or personal injury could result.
Summary of Contents for Secure II 3002
Page 33: ...Optional Pendant Operation 32 ...
Page 46: ...Bed Circuit Boards 45 CPU BOARD 3002 407 950 ...
Page 98: ...Notes 97 ...
Page 101: ...Base Assembly and Options 100 FOOT END HEAD END ...
Page 103: ...Base Assembly and Options 102 HEAD END ...
Page 104: ...Base Assembly and Options 103 HEAD END LEFT SIDE FOOT END ...
Page 105: ...Base Assembly and Options 104 Zoom Option Zoom Option Steer Option ...
Page 106: ...Base Assembly and Options 105 Typical Both Ends Typical Both Ends ...
Page 110: ...109 Lift Assembly Common Assembly part number 3000 200 275 reference only ...
Page 124: ...Notes 121 2 ...
Page 125: ...Base Assembly with Zoomr Option 122 HEAD END ...
Page 127: ...Base Assembly with Zoomr Option 124 HEAD END HEAD END ...
Page 128: ...Base Assembly with Zoomr Option 125 FOOT END 8 Caster Option 6 Caster Option ...
Page 129: ...Base Assembly with Zoomr Option 126 FOOT END HEAD END ...
Page 130: ...Base Assembly with Zoomr Option 127 ...
Page 131: ...Base Assembly with Zoomr Option 128 ...
Page 139: ...Base Assembly with Battery Back Up Option 136 HEAD END HEAD END 2025 31 805 Ground Strap ...
Page 140: ...Base Assembly with Battery Back Up Option 137 ...
Page 141: ...Base Assembly with Battery Back Up Option 138 ...
Page 144: ...Litter Assembly 141 ...
Page 145: ...Litter Assembly 142 ...
Page 146: ...Litter Assembly 143 ...
Page 147: ...Litter Assembly 144 DETAIL A Standard Length Bed 8 Shorter Length Bed ...
Page 149: ...Litter Assembly 146 DETAIL F ...
Page 153: ...Electrical Litter Assembly 150 ...
Page 154: ...Electrical Litter Assembly 151 Siderail Cable Attachment ...
Page 155: ...Electrical Litter Assembly 152 DETAIL C To Gatch Motor See Detail C ...
Page 156: ...Electrical Litter Assembly 153 DETAIL A DETAIL B 115V BED 230V BED ...
Page 157: ...Electrical Litter Assembly 154 SMART TV OPTION UNITED KINGDOM POWER CORD CABLE INSTALLATION ...
Page 159: ...Mechanical Litter Assembly 156 ...
Page 160: ...Mechanical Litter Assembly 157 ...
Page 162: ...Mechanical Litter Assembly 159 SECTION A A A A ...
Page 164: ...Notes 161 ...
Page 169: ...166 Fowler Drive Assembly Standard Fowler Drive Shown ...
Page 178: ...Notes 175 ...
Page 180: ...Optional Scale Bed Exit Assembly 177 FOOT END ...
Page 182: ...Optional HWI Assembly with Communication 179 ...
Page 183: ...Optional HWI Assembly w Communication Ports 180 ...
Page 184: ...Optional HWI Assembly w Communication Ports 181 ...
Page 187: ...Zoom Option Litter Assembly 184 DETAIL A Assembly part number 3002 131 10 reference only ...
Page 188: ...Zoom Option Litter Assembly 185 DISPLAY HOUSING ...
Page 189: ...Zoom Option Litter Assembly 186 On Off Switch Inside Enclosure ...
Page 190: ...Zoom Option Litter Assembly 187 ...
Page 191: ...Zoom Option Litter Assembly 188 ...
Page 194: ...Notes 191 ...
Page 198: ...Battery Back Up Option Head End Enclosure 195 ...
Page 200: ...Head End Siderail Assembly 197 LEFT SIDERAIL SHOWN ...
Page 201: ...Head End Siderail Assembly 198 CARRIER ARM ASSEMBLY LEFT SIDERAIL SHOWN ...
Page 203: ...Head End Siderail Assembly 200 SIDERAIL INNER PANEL ASSEMBLY ...
Page 204: ...Head End Siderail Assembly 201 LEFT HEAD END SIDERAIL WIRE ROUTING ...
Page 205: ...Head End Siderail Assembly 202 RIGHT HEAD END SIDERAIL WIRE ROUTING ...
Page 257: ...2040 120 4 Optional Pleur Evac Rack w Defib Tray 252 ...
Page 263: ...258 3001 333 000 Optional Accessory Adapter Frame ...
Page 268: ...3001 318 20 Optional Bed Extender Assembly 263 C F H C D C D E J ...
Page 269: ...3000 318 50 Optional Bed Extender Mattress 264 ...