33
12.2 Noise emission
Device type
e100 / le100
Battery type used for device
Lithium-ion
Idling
(measured at a distance of 1 m,
according to EN)
[dB(A)]
-
Full load
(measured at a distance of 1 m,
according to EN)
[dB(A)]
-
Idling
(measured at a distance of 4 m,
according to NFPA)
[dB(A)]
67
Full load
(measured at a distance of 4 m,
according to NFPA)
[dB(A)]
70
12.3 Operating and storage temperature ranges
Operating temperature, standard
[°C] /
[°F]
-20 …
+55
-4 …
+131
Operating temperature extreme
range for 9 min., cyclical (device
operational)
[°C] /
[°F]
-20 … +121
-4 …
+250
Ambient temperature, standard
(device not operational)
[°C] /
[°F]
-25 …
+45
-13 …
+113
Ambient temperature extreme range
for 7 min. (device not operational)
[°C] /
[°F]
-30 … +149
-22 …
+300
12.4 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.
(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)
12.5 Torque speci
¿
cation and wrench size for pivot bolt
Device type
e100 / le100
Pivot bolt
M 24 x 1.5
Wrench size
[mm]
30
[in.]
1.18
Torque
[Nm]
100 +10
[lbf
Â
in]
885 + 89
Device including rechargeable battery