BULB INSTALLATION
OBSERVE ALL SAFETY PROCEDURES when working around the xenon bulb. Open the
lamphouse access cover by releasing the clasps and swinging the cover up to its stop. Loosen the (5) quarter-
turn fasteners and remove the two bulb compartment side covers. Verify that the lamphouse is fitted with the
correct support collet appropriate to the desired bulb wattage. The bulb leads and contact clamps are tied down
for shipping. Free the clamps and slide the anode clamp over the brass socket of the rear support collet.
REMOVE THE PLASTIC PROTECTIVE COVER from the xenon bulb only if necessary.
Handle the bulb by the metal end caps
only.
Dismount the anode lead from the (+) end cap of the bulb if
attached. Grasp the bulb by the metal anode (+) end cap
only
when unscrewing the lead from the bulb; DO
NOT hold the bulb at the cathode (-) end cap when removing the anode lead.
INSERT THE BULB into the lamphouse, passing the anode (+) end cap through the center
hole of the reflector. Take care not to bump or scratch the surface of the reflector. Insert the anode (+) pin into
the rear support collet and contact clamp. Rest the cathode (-) end cap in the front bulb support yoke. Seat
the anode (+) pin into the rear support collet as far as possible for correct focus travel. Securely tighten the
socket head clamping screw in the anode contact.
REST THE CATHODE END CAP in the “
V
” of the bulb yoke. Dress the bulb lead directly in
front of the bulb support yoke to minimize the projected shadow, but do not allow it to touch grounded metal
lamphouse components; the bulb yoke and the support casting are insulated from ground. Slide the cathode
contact clamp over the cathode (-) pin and securely tighten the clamping screw.
REMOVE THE PLASTIC COVER from the bulb. Record the bulb serial number, date, and
lamphouse hours on the Xenon Bulb Record on the inside back cover of this manual. Replace the bulb enclo-
sure covers and secure the quarter-turn fasteners. Use of these covers maximizes bulb cooling for long life.
XG4/007
Rear Support Collet
Bulb Socket
Anode Contact Clamp
Anode
Clamping Screw
to Igniter Post
Cathode
Front Bulb Support Yoke
Set Screw
Cathode Contact Clamp
to Negative
Binding Post
Cathode Adapter
(as req’d.)*
* Cathode Adapter & longer Rear Support Collet
are included in the optional Bulb Kit 72-01175
required for 2 kW, 2.5 kW, and 3 kW bulbs.
Summary of Contents for XENON GLADIATOR IV
Page 19: ...LAMPHOUSE WIRING DIAGRAM Barrier Strip 21 62012 see Figure 3 Item 44 XG4 017 ...
Page 21: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 1 0f 3 XG4 019 ...
Page 22: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 2 0f 3 XG4 020 ...
Page 23: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 3 0f 3 XG4 021 ...
Page 28: ...1 2 3 4 5 6 7 8 9 10 12 13 7 14 15 11 XG4 026 FIGURE 1 ...
Page 30: ...FIGURE 2 1 2 3 4 5 6 7 8 XG4 028 ...
Page 36: ...FIGURE 4 Fade Out Heat Filter Assembly XG4 034 ...
Page 38: ...FIGURE 5A Color Boomerang Assembly No 72 00264 XG4 036 ...
Page 40: ...FIGURE 5B Color Boomerang Assembly No 72 00709 XG4 038 ...
Page 42: ...FIGURE 6 Iris Chopper Aperture Assembly XG4 040 ...
Page 44: ...FIGURE 7 XG4 042 ...
Page 47: ......
Page 48: ......