OPERATION
OPEN THE BOOMERANG ACCESS COVER and verify that the round glass heat filter and
ring assembly is installed into the bracket mounted to the fadeout and douser support housing. NOTE: The
coated side
of the filter, with the XX or other marking,
must be facing the reflector
.
REMOVE THE PLASTIC COVER from the xenon bulb. DO NOT ignite the lamp with the
cover on the bulb. Store the cover for future re-use. Replace and secure the bulb enclosure covers.
CLOSE THE LAMPHOUSE COVER and secure using both latches. Turn on the main line
switch and/or circuit breaker to energize the xenon power supply. The spotlight blowers will start and operate
continuously until the xenon power supply is de-energized.
PLACE THE
LAMP
SWITCH in the “ON” position and the lamp will ignite. Check the
reading on the lamphouse ammeter. Nominal current for the 4500 watt xenon bulb is 135 amperes. If using
a lower wattage bulb, check the documentation packaged with the bulb for its current ratings. DO NOT, AT
ANY TIME, exceed maximum rated amperage;
the “wattage” readout on the digital display is an approximate
figure and should not dictate the output setting
. Output current is adjusted at the xenon power supply; see power
supply manual for instructions. Operation of a new bulb is normally started at the lower end of its range, and
current is gradually increased as the bulb ages to maintain light output. During the ignition cycle, the display
will also briefly indicate the high “no load” (open circuit) DC voltage applied to the xenon bulb for ignition.
REMOVE THE REAR COVER above the instrument panel by releasing the (3) quarter-turn
fasteners. This exposes the bulb positioning controls in the lamphouse back casting. To focus the xenon bulb
and obtain the best light on the stage, the two methods outlined below are the most suitable.
MOVE THE SPOT SIZE CONTROL HANDLE (trombone) on the large lens carriage all the
way forward to project the smallest spot possible; place the iris, masking shutters (choppers) and the fadeout
douser blades in their full open positions. Project a spot to a wall or similar flat perpendicular surface opposite
the spotlight position.
XG4/009
THE CENTER SECTION of the bulb
positioning controls is a threaded member that
focuses the bulb in relation to the reflector. Turning
this adjustment moves the bulb in only one plane,
into or away from the reflector. Turning this section
clockwise moves the arc away from the reflector.
The small knurled screw to the left of this section can
be tightened to lock the focusing mechanism after
the following procedures have been completed.
THE LARGE THUMB SCREWS, on
either side of the focusing control, lock the
horizontal and vertical adjustment mechanism
in position.
Summary of Contents for XENON GLADIATOR IV
Page 19: ...LAMPHOUSE WIRING DIAGRAM Barrier Strip 21 62012 see Figure 3 Item 44 XG4 017 ...
Page 21: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 1 0f 3 XG4 019 ...
Page 22: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 2 0f 3 XG4 020 ...
Page 23: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 3 0f 3 XG4 021 ...
Page 28: ...1 2 3 4 5 6 7 8 9 10 12 13 7 14 15 11 XG4 026 FIGURE 1 ...
Page 30: ...FIGURE 2 1 2 3 4 5 6 7 8 XG4 028 ...
Page 36: ...FIGURE 4 Fade Out Heat Filter Assembly XG4 034 ...
Page 38: ...FIGURE 5A Color Boomerang Assembly No 72 00264 XG4 036 ...
Page 40: ...FIGURE 5B Color Boomerang Assembly No 72 00709 XG4 038 ...
Page 42: ...FIGURE 6 Iris Chopper Aperture Assembly XG4 040 ...
Page 44: ...FIGURE 7 XG4 042 ...
Page 47: ......
Page 48: ......