SAFETY PROCEDURES
THE XENON BULB is highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance to
the manufacturers operating instructions. The bulb is stable at room temperature, but may still explode if
dropped or otherwise mishandled.
REFER ALL BULB REPLACEMENT and service to QUALIFIED PERSONNEL with
adequate protective clothing (face shield, clean cotton gloves, welders jacket). For routine lamphouse service,
observe the following rules:
1.
Allow the bulb to cool to room temperature before opening the lamphouse. Put on protective clothing
described above.
2.
De-energize the xenon power supply at the AC source before opening the lamphouse compartment.
3.
When possible, encase the bulb in its protective cover when cleaning or servicing the lamphouse
interior. The bulb, when outside the lamphouse, must be encased in the cover.
4.
Clean the bulb after it has cooled to room temperature. Do not touch the quartz envelope of the bulb;
fingerprints will burn in and create hot spots which may shorten bulb life. If fingermarks are made,
they should be carefully removed with methyl alcohol and cotton prior to bulb operation.
5.
Never view an ignited bulb directly. BLINDNESS OR PERMANENT EYE DAMAGE MAY BE
INCURRED.
6.
Use only xenon bulbs designated as OZONE FREE. When possible, vent the lamphouse exhaust to
outside atmosphere.
7.
Maintain the lamphouse blower in good operating condition. Keep the blower inlet clean for unre-
stricted air flow.
8.
To insure maximum bulb life, operate the lamphouse blower and the exhaust system for
at least
ten
minutes after extinguishing the bulb.
9.
If returning a bulb for warranty adjustment, pack it in its original shipping container. Complete and
return all required warranty information.
10.
Dispose of expired bulbs that are beyond warranty in the following manner: Wrap the bulb tightly in
several layers of canvas or heavy cloth. Place it on a hard surface and shatter the envelope with a sharp
hammer blow. DO NOT place an unshattered bulb in an ordinary refuse container.
11.
DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE
OF XENON BULB HANDLING OR SERVICE.
Anode End Cap
Envelope
Anode Pin
Seal
Anode
Cathode
Seal
Cathode End Cap
Trigger Wire
Cathode
Pin
ST2/006
Summary of Contents for SUPER TROUPER II
Page 2: ......
Page 5: ...ST2 003 ...
Page 26: ...Super Trouper II Lamphouse Xenon Bulb Ignition Monitor Circuit ST2 024 ...
Page 27: ...Super Trouper II Control Circuit ST2 025 ...
Page 30: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 1 0f 3 ST2 028 ...
Page 31: ...23976S DIGITA L DISPL AY CONT ROL CIRCU IT Page 2 0f 3 ST2 029 ...
Page 32: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 3 0f 3 ST2 030 ...
Page 33: ...1 2 3 4 5 6 7 8 9 10 11 FIGURE 1 SUPER TROUPER II Parts List ST2 031 ...
Page 43: ...FIGURE 5 ST2 041 ...
Page 51: ......
Page 52: ......