2.5 Parameter setting
Factory setting:
When delivered the inverter is set to the most common operation conditions. This should always be
checked and adjusted to task required.
For information about the parameter see page 9 and the following pages.
Setting procedure:
Note:
By pressing UP and DOWN simultaneously, when the display shows OFF, the default
setting will be written into all menus.
By pressing UP and DOWN simultaneously, when a MENU is entered, the factory setting
of the present MENU will be stored.
Choosing special operations:
The Speed Commander is equipped with a series of special operating functions (programs), witch can be
set as follows:
1) Push all the 3 buttons STEP/STORE, UP and DOWN simultaneously and connect the mains
power supply. Keep the button pressed until a green “c” appears.
2) The green display shows a ”c” for ”Choice of program” and red display shows a program number
corresponding to operation chosen. The default program no. is 0 ”Normal frequency inverter”.
This manual only covers this function. Please contact supplier for manual for special programs.
(Parameter set up, control wire connection and functional description) All these manuals can be
found in PDF format at www.speed-tech.dk
3) To choose a special operating function: Push UP or DOWN until the display shows the desired
program no. And then select it by pressing the STEP/STORE button. The new program will
automatically be initialized and ready to start.
UNIVERSAL AC MOTOR CONTROLLER
SPEED-COMMANDER VECTOR DIGITAL
STEP
STORE
UP
DOWN
1) Push STEP / STORE and the green
display shows the parameter
number.
2) Push UP or DOWN to change the
value of the parameter.
3) Push STEP / STORE to store any
new value.