14
MA_VEB200-1-2_A2_181015_en
3.2
3.2.1
Needle lever
Mounting (Fig. 5)
A T T E N T I O N !
Switch off machine electrically!
Release screw (1), swivel the thread take-up (2) and remove the needle lever
(3). When mounting the needle lever make sure that the needle is mounted
centrically to the needle channel and that the needle point is flush with the right
hand edge of the left hand needle guide.