The theoretic needle radius of 41,3 mm should be 0,03 mm to 0,05 mm larger
at the left needle guide, 0,01 mm smaller to 0,01 mm larger at the needle glide
plate and 0,06 mm to 0,8 mm larger at the right needle guide.
The settings should be realized with a gauge. Deviations may deteriorate the
sewing result considerably and may cause damages or pre-mature waste of the
sewing tools.
Setting the needle plate (Fig. 1)
3.1.4
Loosen screw (2) to remove the needle glide plate (1). When re-mounting the
needle glide plate make sure that it fits closely to the needle plate bridge.
Replacing the needle glide plate (Fig. 3)
Fig. 3
VEB200-1