22
W: www.streamline.systems E: [email protected] T: +44 (0)1626 830 830
W: www.streamline.systems E: [email protected] T: +44 (0)1626 830 830
23
De-ionising (DI) Resin Beads -
Usage & Replacing
Care and maintenance of your Ecostream™ system will ensure it is well looked after and running
smoothly every time.
It is recommended to run a weekly, monthly and quarterly examination on the Ecostream™ system to
ensure all filters are adequate and effective for producing pure 000ppm water quality.
The DI filter is a vessel containing DI resin beads.
The DI resin cannot be regenerated and needs replacing
should the ‘out’ TDS reading rise above 006ppm.
6
Maintenance & Replacing Filters
Maintenance & Replacing Filters
Weekly inspection
• Keep a check on the pure water TDS by using the handheld TDS meter. This measures
in parts per million (ppm). If the output reads higher than 3ppm, it is recommended to
change the de-ionising (DI) filter, and make a note in the back of the inspection booklet
• Keep a check on the battery voltage by running through the controller function until you reach
‘BAT’. A good healthy battery will read between 11V and 12.4V.
Monthly inspection
• Drain tank completely to clean tank out
Ensure the ECOSTREAM® system is not operating or under pressure when maintenance or
filter replacements are being undertaken.
Disposing of resin beads can create a slippery surface. Care needed to dispose of resin beads
effectively. Remove all over spill immediately
Warning
Warning
To replace the DI resin filter
The Pump
Remove the DI filter from the side of the
Ecostream™ system, by unclipping it and
disconnecting the pipes.
Unscrew the head from the filter body and
tip out the old resin. Refill with new resin
canister with resin ¾ full.
The pump fitted to the Ecostream™
systems are protected by an in-line strainer
filter, with a clear top allowing for visual
inspection. If anydebris accumulates in the
strainers, unscrew the top and flush out with
clean water.
The pump has a built in pressure switch.
When switched on it will pump until it has
reached the maximum pressure setting
before cutting out. This is a safety feature.
However, the pressure switch may burn out if
the pump is allowed to run intermittently.
To avoid this happening, make sure that the
pump speed is correctly set on the flow
controller. The pump must not be stored
under pressure as this will invalidate
the warranty.
PRODUCT CODE: SFDP22-012-100-238
PRODUCT CODE: MB115