background image

User Manual for X5-E0804/E0408 V2.0

For more information, please visit our website

www.en.streamax.com

30 - 44

Network type:

The default one is Mix, 2G/3G ot 2G/3G/4G optional.

Dialing parameter

It includes access point, user name, password, data service number, and

enter SIM parameters provided by the manufacturer. The default is empty, the program comes
with empty arguments by dialing.

Certification

Supports PAP or CHAP.

Remark:

When there is SIM and normal 3G/4G signal, it will dial automatically.

Network- server

Server’s IP address and port are needed for device registering to server. Select CMS if there is

wire or WIFI. Set up central IP and port, Select 4G CMS when dialing wireless network.

By default, there is only one server, but user can add other server up to 6. Server 1 can’t be deleted.

4. VIDEO SURVEILLANCE

4.1. REAL-TIME SURVEILLANCE

Surveillance-->Real-time Surveillance

Real-time Setting Interface

Audio:

Enable the audio when live view the video

Image Setting:

Set the live-view parameters, including brightness, contrast, etc.

Summary of Contents for M1-H0401

Page 1: ...804 E0408 V2 0 For more information please visit our website www en streamax com 1 44 User Manual For X5 E0804 E0408 MDVR V2 0 Mobile Digital Video Recorder Copyright 2013 2015 Streamax Technology Co Ltd All Rights Reserved ...

Page 2: ...any notice The purpose of this manual is to kindly aid the user for the operation for our MDVR The user should have a basic understanding of computer operation and basic knowledge of how to connect peripherals and make some settings Copyright Under copyright laws the content of this manual may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable f...

Page 3: ...tored in a cool and dry place away from direct sunlight flammable or explosive substances etc Keep gaps not less than 3cm around the device to facilitate ventilation for cooling 6 Accessories Make sure to use accessories from the manufacturer recommended in the attachment Insulate circuit ground and metal shell for all the peripherals Before installation please open the package and ensure that all...

Page 4: ...RECORD SEARCH AND EXPORT 17 3 3 LOG SEARCH AND EXPORT 20 3 4 SYSTEM STATUS 21 3 5 BASIC SETUP 23 3 5 1 REGISTER INFOMATION SETUP VEHICLE INFORMATION 23 3 5 2 TIME SETUP 24 3 5 3 START UP 25 3 5 4 USER SETTING 26 3 5 5 NETWORK SETTINGS 28 4 VIDEO SURVEILLANCE 30 4 1 REAL TIME SURVEILLANCE 30 4 2 RECORD 32 4 3 IPC SETUP 34 4 4 DATA COLLECTION 35 4 5 ALARM 36 4 6 MAINTENANCE 38 4 6 1 CONFIGURATION 38...

Page 5: ...design for the shield 4 Combines physical electrical and software anti vibration 5 Supports DC6 36V wide voltage input suitable for 12V and 24V vehicle 6 Adapts dynamic coding technology to adjust the change of 3G network and ensure the fluency of monitoring video 7 Watermark technology prevent data tampering and guarantee the video authenticity and legal efficiency 1 3 FUNCTIONS 1 Local recording...

Page 6: ...lay Split 1 4 9 Image display OSD GPS information alarm temperature acceleration voltage device information software version MCU version network status Operation Interface Semi transparent GUI Recording Video Audio Compression H 264 ADPCM Image Resolution Analog PAL WD1 928X576 WHD1 928X288 WCIF 464X288 D1 704X576 HD1 704x288 CIF 352x288 NTSC WD1 928X480 WHD1 928X240 WCIF 464X240 D1 704x480 HD1 70...

Page 7: ...5 X 2 Sensor 8 inputs 2 outputs Serial G sensor Internal Speed 1 channel pulse speed detection Interface Interface CP4 Optional Power Input DC8 36V Output 1A 12V 1A 5V Physical Characteristics Dimension L x W x H 292 5x215x91 6mm including shelf and back cover Weight 2 6 kg Others Water Proof Rate IP54 1 5 SYSTEM DIAGRAM To connect A ...

Page 8: ...User Manual for X5 E0804 E0408 V2 0 For more information please visit our website www en streamax com 8 44 1 6 EXTERNAL INTERFACE 1 Dimension Unit mm 2 Front Panel and Rear Panel ...

Page 9: ...g SD SD card indicator lamp green GPS GPS Status indicator lamp It is green when there is module otherwise it is light off It flashes when there is position information NET Network indicator lamp It is green when there is 3G 4G module otherwise it is light off It flashes when there is network HTR Heater indicator lamp It is yellow when it is heating or keeping warm PWR Power indicator lamp blue RE...

Page 10: ...cription 3G 4G antenna 3G 4G female port GPS antenna GPS female port Wifi antenna Wifi female port Debug Debug port for engineer CAN port Reserved Audio Video input Power input DC8 36V Amplifier To connect speaker Panel To connect CP4 LAN Network interface connect to network switch etc USB To connect fire proof box Serial port ...

Page 11: ...nual for X5 E0804 E0408 V2 0 For more information please visit our website www en streamax com 11 44 1 7 DESCRIPTION 1 3G 4G port 3G antenna 2 GPS port GPS antenna 3 Wifi port WiFi antenna 4 A V port DB44 wire ...

Page 12: ...or VIDEO AV IN7 black GND red 12V 0 5A white AUDIO no color VIDEO AV IN8 black GND red 12V 0 5A white AUDIO no color VIDEO AV OUT1 black GND red 12V 0 5A white AUDIO no color VIDEO Remarks a From AV IN1 to AV IN8 the former one is 10mm longer than the latter one For example if AV IN1 is 110mm then AV IN2 is 120mm b From AV IN1 to AV IN8 all of them adopt 4 PIN aviation head RS765 4 AV OUT1 adopts ...

Page 13: ...max com 13 44 Signal Remarks a After short circuit PIN 1 and PIN 2 of aviation head connect with red wire b PIN 3 of aviation head connects with yellow wire c After short circuit PIN 6 and PIN 7 of aviation head connect with black wire 6 Amplifier port 7 pin aviation amplifier output wire Signal ...

Page 14: ...User Manual for X5 E0804 E0408 V2 0 For more information please visit our website www en streamax com 14 44 7 Hard disk USB port USB wire Signal ...

Page 15: ... 2 SETTING 2 1 CP4 CONTROL PANEL Repeat Repeat station notification Station Notification Station notification bottom 0 9 Number enter key Confirmation Confirmation key Back Back from the menu Direction Up Down Left Right selection key Operation Instrument Remark When reporting to CMS server use serial number ...

Page 16: ...p left click login picture login screen will pop up 3 Left click on the login button to login and right click to log out Login Notice 1 Software is automatically assigned by user name and password it can be divided into user and administrator privileges 2 Password options can not be closed but it can be set to null when it is empty user do not need to enter the password to login Login interface In...

Page 17: ...r the left click mouse on the remote control a Move the cursor to the number position press Enter or left click mouse button to select the corresponding number b Move the cursor to 123 press Enter or mouse to choose input type such as the Numbers letters or special characters ab means lower case letters 123 means numbers AB means capital letters the highlighted place of background refers to the cu...

Page 18: ...al stream records Select the date with record click next then enter the following interface Following is the record search detail and record search result interface Record search detail interface Record Type User can choose all record alarm record or normal record Channel choose The channel is optional and mark with color that has record The channel with gray cannot be chosen if there is no record...

Page 19: ...eo the button in the middle of screen can switch the channels The image stops and it will not exit automatically when playing to the last video of the day Time period settings Click the time setting button select start time and end time it will backup or playback the video in the selected time period Click clip to export the video the file format can be 264 comprehensive file also can be avi forma...

Page 20: ...ch interface it records and displays all alarm events and login operation log Enter the log query the interface will be shown as following Log Search interface instruction Calendar the date with log will be marked on the calendar with green color Remark There is no color classification in the log mark and all are green ones Log search interface instruction Start time the start time for searching l...

Page 21: ...ent is triggered Log name event content Supports page up page down and export all log files of the specified date Supports link to video file click on button to playback video files Lock log search Log includes the following information Log time the time of when event triggered Log name event content Log will be recorded according to channel number each channel will have a lock log file Support pa...

Page 22: ...User Manual for X5 E0804 E0408 V2 0 For more information please visit our website www en streamax com 22 44 System Version information System Modules System Server status System Environment ...

Page 23: ... website www en streamax com 23 44 System Storage 3 5 BASIC SETUP Click setup button and enter the following interfaces 3 5 1 REGISTER INFOMATION SETUP VEHICLE INFORMATION Register information Device info Device ID Currently it is not useful Register information Vehicle info ...

Page 24: ...n streamax com 24 44 Vehicle Number When connected with PAD the vehicle number is needed Vehicle plate Input manually Line number Input manually Register information About the driver s information Driver number Input manually Driver name Input manually 3 5 2 TIME SETUP Time setup General ...

Page 25: ...ignal changes to valid device will synchronize time Center Server synchronize time with center server NTP server synchronize time with NTP server Remark 1 Synchronize time according to time zone 2 Multi mode can be selected for time synchronization If one works the others take no affect Time setup DST Enable Select to enable Offset After enabling DST adjust the hour manually Mode Setup DST accordi...

Page 26: ...sumption standby mode available Low Voltage Protection Enabling the low voltage shutdown protection mode selected Low Battery Protection Protect the vehicle battery When consistently below the standard value it will countdown shutdown As for a 12V vehicle the default is 9V while a 24V vehicle is 21V Recovery boot voltage values low voltage protection when the battery voltage is consistently greate...

Page 27: ...user and click Delete User button Please be noted that the administrator can not be deleted Supports add user function Click Add User button then enter the following interface Remark 1 Only administrators can add users 2 Users can add up to two 3 User name cannot be empty not the same with the existed user name while the user password can be empty User name and password can be modified Select a us...

Page 28: ...Settings enter the following interface user can set network parameters Network Settings wired network and port interface description Automatically obtain IP Dynamic acquisition DNS can also be statically configured to dynamically obtain Use the following IP Static IP need to use a static DNS Remark Switch from static IP to automatically obtain IP mode it can display dynamic IP but the static IP pa...

Page 29: ...ion of wifi network Enable Select to enable WIFI ESSID Manually input the address of AP Encryption It supports NONE WEP and WPA Password Manually input Static IP Select to use static IP or MDVR will get dynamic IP Network 3G 4G network interface Dialing wireless network user needs to choose the module type and setup dialing parameters No Service When entering the dialing setup interface it search ...

Page 30: ...HAP Remark When there is SIM and normal 3G 4G signal it will dial automatically Network server Server s IP address and port are needed for device registering to server Select CMS if there is wire or WIFI Set up central IP and port Select 4G CMS when dialing wireless network By default there is only one server but user can add other server up to 6 Server 1 can t be deleted 4 VIDEO SURVEILLANCE 4 1 ...

Page 31: ...Setting Interface Screen Totally 32 screens can be added Mode 1x1 2x2 3x3 optional Channel Included channel number Residence time Residence time for each screen Edit Delete or Edit Add screen Add polling screen Auto polling Enable the auto pulling Sub stream Setting Interface Total bandwidth Set the bandwidth default is 500Kbps maximum 5M Transmit mode Default is the recommended smooth clear mode ...

Page 32: ...is PAL NTSC optional Overwrite Enable the HDD to be overwritten when it is full Lock file retention Protect the record file to be deleted by fault default is 7 days Pre recording Pre record before the alarm happens Default is 15min 0 60min optional Main Stream Setting Interface Channel 1 20 channels can be chosen and set the record parameters Enable Enable the main stream record function Resolutio...

Page 33: ...tream Storage The storage type for second stream internal SD or external SD Record mode Mirror record alarm back up and sub stream Mirror record Channel is selectable Video resolution and frame rate are the same with main stream Alarm backup Channel is selectable The parameters are the same with main stream Sub stream Channel is selectable Recording parameters are configurable Mirror channel It is...

Page 34: ... when playback 4 3 IPC SETUP IPC setup Channel 1 16 are default for analog cameras If selected then analog camera is invalid 17 20 channel are for IP cameras Enable IPC Enable to operate IP and port Display channel number and port Setup Search and edit IP camera recording parameters Fast setup Search all the IP cameras in LAN network and auto assign IP address to IP camera ...

Page 35: ... website www en streamax com 35 44 4 4 DATA COLLECTION GENERAL General IO sensor Sensor number 1 8 optional Sensor name IO sensor name OSD name The information embedded to video image Copy Copy the configuration and use it for other sensors General Serial port General speed ...

Page 36: ...onal Calibration mode No need to calibrate if setup as satellite mode 4 5 ALARM GENERAL General Speed alarm Name The current name is Overspeed Enable Enable or disable tick to enable Alarm type 3 levels Trigger Low or high voltage to trigger alarm Linkage When alarm triggered link to alarm output full screen live video report to server and so on General Panic alarm ...

Page 37: ...Low or high voltage to trigger alarm Linkage When alarm is triggered link to alarm output full screen live video report to server and so on General IO alarm interface Name From Sensor1 to Sensor8 Enable Enable this sensor or not tick to enable Alarm type 3 levels Trigger Low or high voltage trigger alarm Linkage Link to sensor out report alarm or full screen IO sensor Alarm linkage interface ...

Page 38: ...rm info to center server or not Full screen When the alarm triggered associate with a single channel to full screen or not Alarm duration time When alarm canceled the alarm duration time during this time if this alarm trigger again It won t be record again 4 6 MAINTENANCE After login click setup Maintenance and then enter into the page as follow 4 6 1 CONFIGURATION In the configuration page user c...

Page 39: ...ile and so on 4 6 3 UPGRADE In the page of upgrade you can upgrade the firmware MCU for MDVR Remark 1 Make sure don t power off during upgrading 2 Put the upgrade file into the folder upgrade which is at the root directory if the USB drive 3 It support upgrade firmware LOGO MCU and MCU for CP4 4 Firmware and MCU will package in one file and it will upgrade MCU first and then firmware 5 The name of...

Page 40: ...l or broken Unformatted Means the HDD has been detected but unformatted New HDD Capacity info Display the correct info means HDD working fine Format Click the Format button to start format if format successful it will start to recording and don t need to restart the format time will be around 10 seconds Remark The new HDD and SD card must be format manually at the first time 4 6 5 DEFAULT In this ...

Page 41: ...X5 E0804 E0408 V2 0 For more information please visit our website www en streamax com 41 44 Remark For language MAC address register info CMS server info speed adaption parameter will not change during default settings ...

Page 42: ...ally this problem results from the incorrect power connection Please follow below steps to check the power connection 1 Check the input power whether the power wire is connected correctly whether the ground wire is connected back to the battery and whether the fuse on the power wire is in good condition 2 Check whether the ACC signal wire input to the power is with voltage higher than 7 V Image 1 ...

Page 43: ...o input into the channel for recording and it must record normally 5 The GPS works abnormally Please follow below steps to check it 1 Check whether the GPS antenna is installed correctly There is a silk print logo on the GPS antenna holder behind the host device 2 Check whether the antenna receiver is sheltered It should not be covered by any stuff which may cause it not to receive signals 3 Envir...

Page 44: ...the MDVR device always been in a state of restart Check whether the MDVR device voltage is insufficient If the device voltage does not reach the start voltage the device will restart Hard disk or SD card may cause the MDVR device unable to start You need to remove the storage device and then boot up to verify whether it is caused by the storage device 14 Why the MDVR device cannot start Check the ...

Reviews: