background image

©Copyright 2021 Strava Solutions, LLC All rights reserved 

PAGE: 4

DANGER!

CAUTION!

WARNING!

Danger indicates an imminently hazardous situation which, if not avoided, will result in death or 

serious injury.

European Union CE mark.

The CE mark indicates that this 

product satisfies the relevant 

requirements of EC Directives.

Electric Shock

The Electric Shock Symbol is 

used to indicate a hazard arising 

from dangerous voltage. Any 

mishandling could result in severe 

injury or death.

Waste Electrical and Electronic 

Equipment (WEEE)

This symbol on the product or on 

its packaging indicates that this 

product must not be disposed of 

with regular waste. Instead, it is the 

user’s responsibility to dispose of 

waste equipment according to the 

local laws. Separate collection and 

recycling of the waste equipment 

at the time of disposal will help 

conserve natural resources and 

ensure it is recycled in a manner 

that protects human health and 

the environment. For information 

about where the user can drop off 

the waste equipment for recycling, 

please contact your local waste 

collection authority.

Caution, consult the 

instructions for use.

Keep dry

Refer to User Manual

Product Certification Mark

Year of Manufacture

Catalogue Number

Caution indicates a potentially hazardous situation which, if not avoided, may result in property 

damage or minor injury or both.

Warning indicates a potentially hazardous situation which, if not avoided, could result in death or 

serious injury.

Failure to follow these instructions could result in damage to your new heating appliance and/or injury

DANGER!

CAUTION!

WARNING!

Signal words are used in this manual and apply to hazards or unsafe 
practices which could result in personal injury or property damage. See the 

information below for definitions of the signal words.

SYMBOLS

This symbol designates where personal injury or damage to the equipment is possible.

Summary of Contents for 100.500

Page 1: ...dard Size REF 100 500 Rolyan Standard Size REF 100 600E Strava Euro REF 100 500E Rolyan Euro REF 100 600A Strava Aussie REF 100 500A Rolyan Aussie REF 100 600UK Strava UK REF 100 500UK Rolyan UK This...

Page 2: ...Unit Instructions 7 Initial Set Up Function Check 7 General Use 8 Storage and Handling 9 Error Messages on Control Panel 9 Glass Replacement 10 UV Ballast Replacement 11 Pump Occlusion 13 Heating Ele...

Page 3: ...the product before using the splint bath The Electric Shock Symbol is used to indicate a hazard arising from dangerous voltage Any mishandling could result in severe injury or death The Exclamation Sy...

Page 4: ...natural resources and ensure it is recycled in a manner that protects human health and the environment For information about where the user can drop off the waste equipment for recycling please conta...

Page 5: ...erature Variability F C 2o Sanitation Mode F 185o Set Time Seconds 30 180 Storage Altitude ft 16 732 ft Operation Max ft 16 732 ft m 5100 m m 5100 m C 85o Over Voltage W 11 Frequency Hz 50 60 Hz Mains...

Page 6: ...ets wheel 8 Temp control up or down 9 Menu 10 Add a new preset 11 Power down unit 4 8 7 9 4 8 7 10 11 2 1 3 5 6 Top Side of Unit Side of Unit 25 5cm 10 60cm 22 625 52cm 19 75 Rear of Unit Inner Tub 30...

Page 7: ...f the bath the start up wizard will display on the LCD screen Start up wizard will prompt user to set time day of the week and temperature Note Sanitation cycle defaults to on 2 Unit must be primed be...

Page 8: ...press start Once the bath is empty proceed with tank cleaning Strava recommends a minimum of a monthly water reservoir cleaning more frequently if conditions warrant it Turn the power switch off and u...

Page 9: ...Carefully remove black rubber boot from UV housing allowing the lamp to slide out of the housing Disconnect lamp from connectors on both ends Replace bulb Reconnect at both ends and insert new bulb ba...

Page 10: ...rame and ensuring that the glass edge is on track Figure 8 Complete the hardware install by installing the remaining two sex bolt assemblies into the hinges securing all 4 sets with a hand tight Figur...

Page 11: ...en wrench Figure 15 Lift the scissor drawer out of chassis providing access to the internal control panel Figure 16 Step 2 Remove the old UV ballast Pull out the existing UV bulb from the UV housing a...

Page 12: ...crew using a 1 Phillips screwdriver Reinsert the UV bulb into the black harness socket Feed the bulb into the UV stainless steel vessel sliding the black rubber grommet over the back of the vessel Fig...

Page 13: ...ng on the UV stainless steel vessel closest to the back panel Figure 33 Slide flat head screwdriver between the fitting and the hose Push up slowly to slide the silicon hose off of the fitting Figure...

Page 14: ...ighten with the wire ties aligning them on top of the foam strips of pump important be certain that the wire tie buckles are acclimated to the side of the pump not top Figure 46 47 With pump in one ha...

Page 15: ...panel Figure 58 Once back panel is removed fold it away from you Remove the two mains screws from the heater with a 2 Phillips screwdriver discard screws at this time Figure 59 60 With the provided 1...

Page 16: ...the connector Turn the unit on The software upgrade is complete when the set up wizard appears on the screen Step 3 Reassemble the unit Fold the back panel into place aligning the screw holes on eith...

Page 17: ...d replacement or repair be required purchaser must notify dealer or manufacturer in writing After obtaining an RA returned goods authorization product must be returned in original packaging We estimat...

Page 18: ...Strava Solutions LLC 2733 Kanasita Drive 125 Hixson TN 37343 USA TEL 1 423 313 6157 EMAIL info kismetus com technicalservice kismetus com www Stravasolutions com MANUFACTURED BY...

Reviews: