background image

Connecting External Components to the System

Connecting and Powering On the System

2-25

5. Pull the innermost section of the rail out until it stops. Then pull the green release 

button, and pull the inner section completely out of the assembly (

Figure 2-19

). 

Repeat for the other side.

Figure 2-19. Extending the Rails 

1

Green release button

Summary of Contents for ftServer V 2302

Page 1: ...Stratus Technologies R003S 02 Stratus ftServer V 2302 V 4304 and V 6308 Hardware Installation Guide ...

Page 2: ...r use by Stratus personnel and are subject to change without warning This document is protected by copyright All rights are reserved Stratus Technologies grants you limited permission to download and print a reasonable number of copies of this document or any portions thereof without change for your internal use only provided you retain all copyright notices and other restrictive legends and or no...

Page 3: ...abilizing the System 1 18 Disposing of Shipping Materials 1 19 2 Connecting and Powering On the System 2 1 Connecting External Components to the System 2 1 Connecting the RSN Console Server 2 1 Connecting the AA E97900 RSN Console Server to the Internet 2 3 Connecting the AA E97900 RSN Console Server to a Modem 2 7 Connecting the AA E97700 RSN Internet Console Server to the Internet 2 10 Connectin...

Page 4: ... 2 33 Appendix A Cabling Reference A 1 Fibre Channel Connections A 1 Fibre Channel Connections to ftScalable Storage RAID Controller Trays A 1 FC Connections to Tape Drive Enclosures A 3 Fibre Channel Cables A 3 Network Connections A 3 Maintenance Network A 4 Ethernet Network A 7 Network I O Enclosure PICMG 2 16 Adapter Cables A 8 Serial Null Modem Cable Connections A 8 PC Console and UPS Connecti...

Page 5: ...e 2 2 AA E97900 RSN Console Server Serial Connection 2 4 Figure 2 3 Connecting the AA E97900 Power Cord and Cables in an Internet Connection 2 5 Figure 2 4 AA E97900 RSN Console Server Connections to a Modem 2 7 Figure 2 5 Connecting the AA E97900 RSN Console Server Cables and Power 2 9 Figure 2 6 AA E97700 RSN Internet Console Server Connections 2 11 Figure 2 7 Connecting the AA E97700 Power Cord...

Page 6: ...Scalable Storage Controller Tray 2 31 Figure 2 25 Powering On the Optional ftScalable Storage Expansion Trays 2 31 Figure 2 26 Powering On the Network I O Enclosure 2 32 Figure 2 27 Powering On the Fibre Channel Tape Drive 2 32 Figure 2 28 Powering On the System 2 33 Figure A 1 V 2302 FC Connections A 2 Figure A 2 V 4304 and V 6308 FC Connections with Switches A 2 Figure A 3 V 2302 Maintenance Net...

Page 7: ...es 1 18 Table 2 1 RSN Console Server Connections 2 2 Table A 1 Optical Fibre Channel Cables A 3 Table A 2 Network I O Enclosure Communications Cable A 8 Table A 3 Null Modem Cables A 9 Table A 4 Cable Length and Component Location Considerations A 9 ...

Page 8: ...Tables vi Stratus ftServer V 2302 V 4304 and V 6308 Hardware Installation Guide R003S ...

Page 9: ...ems Because the internal components of an OpenVOS ftServer system are installed before arriving at a customer site this manual documents only the procedures necessary for setting up a customer system Revision Information This manual is a revision It adds information about installing the AA E97900 RSN console server to the Internet or to a modem and about related null modem and PC cable lengths Not...

Page 10: ...eration of an ftServer system Typographical Conventions This document uses the following notation conventions Italics introduces or defines new terms For example The master disk is the name of the member disk from which the module was booted Boldface emphasizes words in text For example Every module must have a copy of the module_start_up cm file Monospace represents text that would appear on your...

Page 11: ...printed manuals do one of the following If you are in North America call the Stratus Customer Assistance Center CAC at 800 221 6588 or 800 828 8513 24 hours a day 7 days a week If you are located outside North America contact your nearest Stratus sales office CAC office or distributor for CAC phone numbers outside the U S see http www stratus com go support ftserver location Online support from St...

Page 12: ...RSN The comment_on_manual command is documented in the document OpenVOS System Administration Administering and Customizing a System R281 and the OpenVOS Commands Reference Manual R098 There are two ways you can use this command to send your comments If your comments are brief type comment_on_manual press Enter or Return and complete the data entry form that appears on your screen When you have co...

Page 13: ...ll assist Stratus Information Development in making any needed changes to the ftServer system documentation Your assistance is most appreciated Regulatory Notice All regulatory notices are provided in the site planning guide for your system ...

Page 14: ...Preface xii Stratus ftServer V 2302 V 4304 and V 6308 Hardware Installation Guide R003S ...

Page 15: ...m on page 1 18 Disposing of Shipping Materials on page 1 19 Safety Considerations To ensure a safe and effective installation follow the procedures exactly as they are written in this manual Before installing the system take the following important precautions Do not attempt to install the system without the assistance of another able bodied person The size and weight of the system do not allow it...

Page 16: ...ds Use of the locking power cords ensures proper grounding of the system W A R N I N G The system uses two if your system does not include a network I O enclosure or four if your system includes a network I O enclosure power cords to provide redundant sources of power To fully remove power from a system disconnect all power cords To reduce the risk that electrical shock could injure a person or da...

Page 17: ...ch is secured to a shipping pallet by exterior tie down straps Inside the cardboard interior straps secure the cabinet to the pallet A ramp for rolling the cabinet off the pallet is attached to the front of the shipping container along with two transition plates which you use to secure the ramp to the pallet A lever bar is secured to the ramp for use in tipping the cabinet to remove it from the pa...

Page 18: ... C A U T I O N If you received the wrong shipment or if a handling indicator has been activated do not proceed with the unpacking Contact the CAC immediately 3 Verify that the area through which you must move the system has adequate clearance as the following figures indicate Figure 1 2 shows the dimensions of a packaged 38U cabinet Figure 1 3 shows the clearances required at the installation site...

Page 19: ...imensions of a Packaged 38U Cabinet Figure 1 3 Clearances Required at the Installation Site upk002a 80 in 2m 41 in 104 14 cm 53 in 134 62 cm 5 in 12 7 cm 38U Cabinet msys046 Cabinet on Pallet Pallet Ramp Unload From This End 42 in 107 cm 42 in 107 cm 150 in 381 cm 42 in 107 cm ...

Page 20: ...net to the Installation Site W A R N I N G To avoid personal injury or damage to the system two persons are required to move unpack and install an ftServer system Because of the size and weight of ftServer systems have professional movers deliver and move the packaged units to the installation site C A U T I O N To prevent or minimize condensation on the system s internal and external surfaces avo...

Page 21: ...s are required to perform the following procedures 1 Orient the system package so that the package and the ramp have as a minimum the clearance shown in Figure 1 3 Also verify that you have enough clearance above the system to remove the top cardboard cap 2 With one person holding the ramp in place use the metal shears to cut the exterior shipping straps To avoid injury while cutting each strap ho...

Page 22: ...ramp are two accessory boxes which contain various components and documentation Remove the boxes and set them aside for later use N O T E It is possible that the system will include only one accessory box 4 Remove the cardboard pieces of packing material surrounding the cabinet see Figure 1 5 These pieces include two C fold sleeves around the sides of the cabinet and two caps at the top upk003a ...

Page 23: ... the cabinet C A U T I O N If condensation exists inside the plastic wrap you must provide a stabilization period for the system Stabilizing the System on page 1 18 provides complete information about the stabilization process 6 Use the strap buckles to loosen the interior shipping straps that secure the cabinet to the pallet See Figure 1 6 upk004 ...

Page 24: ...the top front and top rear of the cabinet 8 Loosen but do not remove the bolts that secure the wooden restraint blocks to the pallet at the bottom sides of the cabinet See Figure 1 7 Note that there are no bolts on the wooden restraint blocks at the bottom rear of the cabinet To loosen the bolts use the 9 16 inch socket wrench You may need to hold the nut underneath the pallet that secures the bol...

Page 25: ...estraint Blocks 9 Loosen and remove the bolts that secure the wooden restraint block at the front door of the cabinet Then remove the block 10 Remove the lever bar from its storage location see Figure 1 1 and insert it in the center slot of one of the sides as shown in Figure 1 8 upk006a Bolts ...

Page 26: ...ons Serious personal injury and damage to or destruction of the system is possible if the procedure is attempted by only one person 11 Standing near the lever bar and with your assistant on the opposite side of the cabinet as shown in Figure 1 9 push down on the lever with your foot and carefully guide the cabinet with your arms tilting it toward the other person who supports the cabinet upk007b B...

Page 27: ...ng the Cabinet 1 13 Figure 1 9 Tilting the Cabinet 12 While the system is tilted reach down and slide the wooden restraint blocks to the side and out from under the system See Figure 1 10 Figure 1 10 Sliding Back the Wooden Restraint Blocks upk008a msys102 ...

Page 28: ...her The ramp is secured to the front of the cabinet on the pallet To assemble the pallet ramp and secure it to the pallet perform the following procedure 1 With the pallet ramp separated from the pallet performed in step 3 in the previous procedure remove the bolt see Figure 1 11 at the upper edge of the ramp and separate the lower end of the pallet ramp Figure 1 11 Removing the Bolt 2 Fit the bev...

Page 29: ...g Up the Pallet Ramp Unpacking and Positioning the Cabinet 1 15 Figure 1 12 Assembling and Positioning the Ramp 3 Position the pallet ramp under the pallet at the front of the cabinet see Figure 1 12 upk010a ...

Page 30: ...abinet Figure 1 13 Attaching the Transition Plates Removing the Cabinet from the Pallet W A R N I N G Two persons are required to remove the cabinet from the pallet 1 With the help of another person slowly and carefully roll the cabinet down the ramp with one person at the front and one at the back See Figure 1 14 Each person must hold the upper portion of the cabinet with both hands W A R N I N G...

Page 31: ...pen the rear door of the cabinet From the bottom of the cabinet remove and discard the desiccant bags 2 Check the cabinet and system for damage Verify that the cabinets and panels have no dents scratches or scrapes If you noticed damage contact the CAC Verifying the Stratus Serial Number Find the equipment label to check the Stratus serial number To find the equipment label open the rear door of t...

Page 32: ... it stand unpacked and without its plastic wrap in the open air of an office environment 1 Inspect the system for condensation Use the guidelines in Table 1 1 to determine if the system requires a stabilization period before you install it and power it on 2 After the stabilization period if you still notice signs of condensation inside or outside the cabinet allow an additional stabilization perio...

Page 33: ...gns of condensation C A U T I O N Before you power on the system verify that the installation site environment meets the environmental operation and power requirements specified in the Stratus ftServer V 2302 V 4304 and V 6308 Systems Site Planning Guide R624 Disposing of Shipping Materials The shipping materials contain no hazardous materials dispose of them according to applicable procedures or ...

Page 34: ...Disposing of Shipping Materials 1 20 Stratus ftServer V 2302 V 4304 and V 6308 Hardware Installation Guide R003S ...

Page 35: ...closure on page 2 22 Connecting the RSN Console Server Connecting a system to the Stratus RSN allows the CAC to remotely diagnose troubleshoot and resolve problems online To connect to the RSN ftServer systems use a modem or an Internet connection For information on processes files and commands required for RSN support see OpenVOS System Administration Administering and Customizing a System R281 W...

Page 36: ...ummarizes how the RSN console servers connect to the RSN C A U T I O N You must install the RSN console server and modem if present on a flat surface such as a table or rack space Do not place these components on top of a system cabinet Table 2 1 RSN Console Server Connections RSN Console Server Connects to Internet Connects to Modem Dialup AA E97900 Yes Yes AA C72100 modem AA E97700 Yes No AA E96...

Page 37: ...ure 2 1 shows the AA E97900 RSN console server connections to the Internet Figure 2 1 AA E97900 RSN Console Server Connections to the Internet 1 COM 1 port 5 Ethernet cable 2 RJ 45 to DB 9 serial cable 6 Ethernet port LAN2 3 Ethernet switch port 21 7 Ethernet port LAN1 4 AA E97900 RSN console server 3 5 4 6 7 2 1 Network connection to Internet vos239 ...

Page 38: ...p to perform this procedure 1 Connect the RS 232 cable RJ 45 number 2 in Figure 2 2 to serial port 1 on the console server number 1 in Figure 2 2 and to the COM 1 port top port on the server s backplane number 1 in Figure 2 1 N O T E This is not a required connection The CAC uses it as a manual connection from the PC console if a Telnet connection is not available Figure 2 2 AA E97900 RSN Console ...

Page 39: ...nternet Connection 3 Connect the Ethernet cable number 3 from the Ethernet switch to the LAN2 port the upper port of the console server 4 Connect the Ethernet cable number 4 from the external network to the LAN1 port the lower port of the console server 5 Turn the console server power switch to the on 1 position 1 Power switch 4 Ethernet cable from port LAN1 to Internet 2 Power cord 5 RJ 45 to DB ...

Page 40: ...f the console server by sending an RSN mail message to the Stratus Customer Assistance Center CAC or your authorized Stratus service representative and asking them to connect to your server If the console server is not working the CAC or your authorized Stratus service representative will help Connecting the AA E97900 RSN Console Server to a Modem ...

Page 41: ... 4 shows the AA E97900 RSN console server connections to a modem Figure 2 4 AA E97900 RSN Console Server Connections to a Modem 1 COM 1 port 6 Ethernet port LAN2 2 RJ 45 to DB 9 serial cable 7 RJ 45 to DB 25 serial cable 3 Ethernet switch port 21 8 AA C72100 modem 4 AA E97900 RSN console server 9 Phone line 5 Ethernet cable 3 5 4 6 2 1 vos239a 7 8 9 ...

Page 42: ... Wear an ESD wrist strap to perform this procedure 1 Connect the RS 232 cable number 4 in Figure 2 5 to serial port 1 on the console server and to the COM 1 port top port on the server s backplane number 1 in Figure 2 4 N O T E This is not a required connection The CAC uses it as a manual connection from the PC console if a Telnet connection is not available 2 With the console server power switch ...

Page 43: ...console server 4 Connect the other end of the serial cable number 7 in Figure 2 4 to the AA C72100 modem number 8 in Figure 2 4 5 Connect a telephone line number 9 in Figure 2 4 from the modem to a wall jack 6 Connect the Ethernet cable number 3 in Figure 2 5 to port LAN2 the upper port on the console server 1 Power switch 4 Serial cable to port 1 2 Power cord 5 Serial cable to port 2 3 Ethernet c...

Page 44: ...ct the problem Connecting the AA E97700 RSN Internet Console Server to the Internet Perform the following procedure to install the AA E97700 RSN Internet console server N O T E S 1 The AA E97700 RSN Internet console server requires OpenVOS Release 17 1 0 or later 2 Wear an ESD wrist strap to perform this procedure 1 Connect the RS 232 cable RJ 45 from serial port 1 on the RSN Internet console serv...

Page 45: ...tions 2 Connect a Category 5 Ethernet cable from the external network to the RSN console server s LAN1 Ethernet port see callout 7 in Figure 2 6 1 COM 1 port 5 RSN Internet console server 2 Serial line 6 Ethernet port LAN2 3 U772 Ethernet switch port 21 7 Ethernet port LAN1 4 Ethernet cable 3 4 5 6 7 2 1 Network connection to Internet vos236c ...

Page 46: ...ver s LAN2 Ethernet port see callouts 3 4 and 6 in Figure 2 6 N O T E If a longer Ethernet cable is required customers must supply it 4 With the RSN console server power switch in the off 0 position plug the power cord into the console server 100 240 VAC VDC connector and into the AC wall outlet Figure 2 7 Figure 2 7 Connecting the AA E97700 Power Cord 5 Turn the RSN console server power switch to...

Page 47: ...equires one analog telephone line for a connection to the modem as well as a telephone line to use when calling for service 2 Wear an ESD wrist strap to perform this procedure 1 Connect the DB 25 RS 232 cable marketing ID B10102 10 from serial port 1 on the RSN console server to the DTE connector on the modem see callouts 2 and 4 in Figure 2 8 Tighten the connector screws Figure 2 8 Connecting RSN...

Page 48: ...sole Server s Ethernet Cable and Power Cord 3 Connect the RSN console server s power cord to the console server 7 24 VDC connector number 3 in Figure 2 9 to the AC wall outlet number 4 in the figure 4 Connect a DB 9 RS 232 null modem cable marketing ID B10106 25 number 1 in Figure 2 10 from serial port 2 of the RSN console server number 2 in the figure to the COM 1 port top port on the rear of the...

Page 49: ... PC console if a Telnet connection is not available Figure 2 10 Connecting RSN Dialup Console Server to COM 1 Port 5 Connect one end of the customer supplied telephone line to the modem connector labeled PHONE on the modem and connect the other end to the telephone wall jack Figure 2 11 1 DB 9 RS 232 cable from RSN console server serial port 2 2 RSN console server asys078 1 2 ...

Page 50: ...R connector and to the AC wall outlet Figure 2 11 Connecting the ftScalable Storage System The ftScalable Storage system is pre connected before arriving at a customer site but if you need more information see the ftScalable Storage Getting Started Guide R601 N O T E V 2302 V 4304 and V 6308 systems do not support ftScalable Storage G2 systems 1 Telephone line to wall jack 3 Power cord 2 DB 25 RS ...

Page 51: ...terminal emulation software See the OpenVOS System Administration Configuring a System R287 manual for information about how to configure the emulation software on the PC console Perform the following procedure to connect the PC console to the ftServer system 1 Use the Stratus provided DB 9 female asynchronous null modem cable marketing ID B20253 25 to connect the COM 2 port on the ftServer module...

Page 52: ...tion Guide R003S Figure 2 12 Connecting the PC Console to the COM 2 Port 2 Connect a customer provided Category 5 Ethernet cable from the Ethernet port on the PC console to port 21 of U772 Ethernet Switch B see numbers 1 and 2 in Figure 2 13 1 DB 9 cable from COM 2 port 2 Serial port on PC console asys078a 1 2 ...

Page 53: ...o the System Connecting and Powering On the System 2 19 Figure 2 13 Connecting the PC Console to U772 Ethernet Switch B 1 Port 21 of U772 Ethernet Switch B 3 Customer supplied Ethernet cable 2 Ethernet port on PC console vos063c 1 2 3 ...

Page 54: ... and V 6308 Systems Site Planning Guide R624 for a list of qualified UPS models W A R N I N G Hard wiring the AC input and output cords to the UPS unit must be performed by a qualified electrician in compliance with local and national electrical code An electrician must supply and hard wire an appropriate AC input cord to each UPS unit For UPS models not qualified by Stratus you must work with the...

Page 55: ...Figure 2 14 Connecting the UPS Units to the U772 Ethernet Switches 1 A side UPS 4 Port 23 of U772 Ethernet Switch A 2 B side UPS 5 Port 23 of U772 Ethernet Switch B 3 Customer supplied Ethernet cable vos063d 13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 ...

Page 56: ... tasks to install the optional tape drive enclosure in your ftServer module You will need a 2 Phillips screwdriver a large flathead screwdriver and a cage nut tool to perform the installation 1 At the front and rear of the cabinet install cage nuts in the following locations see Figure 2 15 First U bottom hole First U top hole Figure 2 15 Installing Cage Nuts 1 Locations to install cage nuts ...

Page 57: ...m 2 23 2 Loosen the two screws at the rear of the rail to allow the adjustable section to slide Figure 2 16 Figure 2 16 Loosening the Screws on the Rail 3 Secure the rails using two screws in the front and two in the rear Figure 2 17 Figure 2 17 Securing the Rails 1 Screws 1 Screws ...

Page 58: ...4 Stratus ftServer V 2302 V 4304 and V 6308 Hardware Installation Guide R003S 4 Tighten the two screws that hold the adjustable section Figure 2 18 Repeat for the other side Figure 2 18 Tightening the Screws that Hold the Adjustable Section 1 Screws ...

Page 59: ...ng On the System 2 25 5 Pull the innermost section of the rail out until it stops Then pull the green release button and pull the inner section completely out of the assembly Figure 2 19 Repeat for the other side Figure 2 19 Extending the Rails 1 Green release button ...

Page 60: ...nstallation Guide R003S 6 Position the inner rail section on the side of the enclosure so that the green release button is at the front facing out Secure with three small screws per side Figure 2 20 N O T E The rail will extend past the back of the enclosure Figure 2 20 Securing the Inner Rail 1 Screws ...

Page 61: ... the rails in the cabinet Slide the enclosure into the cabinet until it stops in the extended position Figure 2 21 Figure 2 21 Installing the Enclosure 8 Pull the green release buttons both sides and slide the enclosure completely into the cabinet 9 Screw in the two thumbscrews located directly below each of the handles to secure the enclosure to the front vertical rails ...

Page 62: ...r FC HBA port in CPU I O enclosure 10 b If you have dual tape drives available for V 4304 and V 6308 systems only connect the LC optical cable for the right tape drive as viewed from the rear to the lower FC HBA port in CPU I O enclosure 10 Connect the LC optical cable for the left tape drive as viewed from the rear to the lower FC HBA port in CPU I O enclosure 11 Figure 2 22 Connecting the LC Opt...

Page 63: ...Components Perform the following steps to power on the system s components 1 To power on the PDUs perform steps a through c for each PDU in the system N O T E S 1 The system has four PDUs if it is shipped with a network I O enclosure or is shipped with a full complement six of ftScalable Storage trays The system has two PDUs if it is shipped without a network I O enclosure and less than six ftScal...

Page 64: ...re Installation Guide R003S Figure 2 23 Powering On the PDUs 2 Turn on the power switch on the UPS units if connected See the UPS manufacturer s documentation for more information 1 Power breaker switch 3 Power jumper cords 2 Power input cord 4 Blank side of PDU 1 2 3 4 vos229 ...

Page 65: ...tches on the power supplies in the ftScalable Storage controller tray Figure 2 24 and any optional ftScalable Storage expansion trays Figure 2 25 Figure 2 24 Powering On the ftScalable Storage Controller Tray Figure 2 25 Powering On the Optional ftScalable Storage Expansion Trays 1 Power button 1 Power button 1 1 1 1 ...

Page 66: ...Figure 2 26 Powering On the Network I O Enclosure 5 At the front of the cabinet turn on the power switch on the fibre channel tape drive Figure 2 27 Figure 2 27 Powering On the Fibre Channel Tape Drive 6 Turn on the power switch on the side of the C720V modem Figure 2 11 7 Power on the PC console See the PC console s documentation for more information vos071a Power switch DLT SDLT 600 DLT SDLT 600...

Page 67: ...ntation Stratus ftServer Systems Peripherals Site Planning Guide R582 ftScalable Storage Commands Reference Manual R599 ftScalable Storage Operation and Maintenance Guide R600 ftScalable Storage Getting Started Guide R601 ftScalable Storage System Administrator s Guide R604 Stratus ftServer Network I O Enclosure Guide R608 Stratus ftServer V 2302 V 4304 and V 6308 Systems Site Planning Guide R624 ...

Page 68: ...Related Documentation 2 34 Stratus ftServer V 2302 V 4304 and V 6308 Hardware Installation Guide R003S ...

Page 69: ...ctions to ftScalable Storage systems Optical Fibre Channel host bus adapters HBAs in the CPU I O enclosures provide connection points to ftScalable Storage RAID controller trays and to optional tape drives This section discusses the following topics Fibre Channel Connections to ftScalable Storage RAID Controller Trays on page A 1 FC Connections to Tape Drive Enclosures on page A 3 Fibre Channel Ca...

Page 70: ...2 illustrates these connections Figure A 2 V 4304 and V 6308 FC Connections with Switches For information about connecting the ftScalable Storage system see Connecting the ftScalable Storage System on page 2 16 vos195b ftScalable Storage RAID Controller Tray 1 ftScalable Storage RAID Controller Tray 2 CPU I O Enclosure 10 CPU I O Enclosure 11 vos195a Fibre Channel Switch 1 ftScalable Storage RAID ...

Page 71: ...r PCI adapters see Stratus ftServer Systems Peripherals Site Planning Guide R582 Fibre Channel Cables Table A 1 lists the available optical Fibre Channel cables Network Connections This section provides information about the maintenance network that interconnects the system components Ethernet network and Ethernet subnet requirements It discusses the following topics Maintenance Network on page A ...

Page 72: ...d you can connect the site Ethernet ports hubs or switches that you supply to unused Ethernet adapter ports in the ftServer system N O T E S 1 The maintenance network is reserved for Stratus support and maintenance operations only Do not connect any other devices to it 2 The U772 24 Port 10 100 Ethernet Switch is the only supported switch You cannot use any other type of hub or switch in the maint...

Page 73: ...e maintenance network Ethernet and RS 232 connections for ftServer V 4304 and V 6308 systems vos207a CPU I O Enclosure 10 CPU I O Enclosure 11 ftScalable Storage RAID Controller A RAID Controller B ftScalable Storage RAID Controller A RAID Controller B Enet Switch 1 Enet Switch 2 Console PC RSN Console Server RSN Modem UPS 1 UPS 2 ...

Page 74: ...ntenance Network Ethernet and RS 232 Connections vos196a CPU I O Enclosure 10 CPU I O Enclosure 11 ftScalable Storage RAID Controller A RAID Controller B ftScalable Storage RAID Controller A RAID Controller B Enet Switch 1 Enet Switch 2 Fibre Channel Switch A Fibre Channel Switch B Console PC RSN Console Server RSN Modem UPS 1 UPS 2 ...

Page 75: ...e systems four cables In V 4304 and V 6308 systems between each Fibre Channel switch and a U772 Ethernet switch Each FC switch connects to a different Ethernet switch two cables Between the RSN console and one U772 Ethernet switch one cable Between the customer supplied PC console and one U772 Ethernet switch for system console control of the ftServer system one cable Optionally between port 25 of...

Page 76: ...CMG 2 16 adapters Serial Null Modem Cable Connections Locate the system within reach of the null modem cables required for the following connections Between the ftServer system backplane and the PC console Between the ftServer system backplane and the RSN console server Between the RSN console server and the modem Table A 3 describes the required null modem cables Table A 2 Network I O Enclosure C...

Page 77: ... RJ 45 to DB 25 male cable provided with the console server for connecting port 2 of the RSN console server to serial port 1 on the RSN modem AW B20260 015 5 ft 1 5m AA E96600 RSN console server to the system backplane One DB 9 female to DB 9 female null modem cable provided with the console server for connecting port 1 of the RSN console server to the serial COM 1 port on the system backplane B10...

Page 78: ...ystem 15 ft 4 57m 25 ft 7 62m RSN modem RSN console server Locate the RSN modem as follows AA E97900 and AA E97700 cable AW B20260 015 locate less than 5 ft from the RSN console server AA E96600 cable B10102 10 locate less than 10 ft from the RSN console server 5 ft 1 52m 10 ft 3 05m UPS units ftServer system Locate each UPS unit less than 8 ft away from the PDUs in the system cabinet length of PD...