![Strategic Vista DGR1100 Series Instruction Manual Download Page 12](http://html1.mh-extra.com/html/strategic-vista/dgr1100-series/dgr1100-series_instruction-manual_1383703012.webp)
11
ALARM
Alarm Enable
– Enables / disables Alarm feature to function.
Alarm Duration
– Set the amount of time for recording to occur during an Alarm.
Default setting is 1 sec. Available durations available are:
(10 sec, 15 sec. 20 sec, 30 sec, 60 sec, 2 min,
3 min, 5 min, 10 min, 30 min, 60 min, Always).
Record IPS
– Sets the Images Per Second of recording during an Alarm.
Default setting is 60 IPS. Available IPS settings are: 60, 30, 15, 8,
4, 2 & 1.
Record Quality
– Sets the Quality of recording during an Alarm. Available
settings are: Basic, Normal, High and Best
Record Mode
– Sets the Record Mode between Frame and Field for recording
during an Alarm. The default setting is Field.
(Alarm)
►
Alarm Enable: Yes
Alarm Duration: 1 MIN
Record IPS: 60
Record Quality: High
Record Mode: Frame
REMOTE
Remote Mode
– Select RS-232 or RS-485 interface for the remote computer
connection protocol. Please refer to Appendix #3 for PIN configuration,
and page 14 for more information on Remote Protocol.
Baud Rate
– Set the speed of the remote computer’s Baud Rate - which is the rate
of data transmission. Available Baud Rates are: 1200, 2400, 4800,
9600, 19200, 57600, 115200.
ID
– You can use RS-232 remote protocol to program different DVR’s. You can set a unique ID for this DVR
system which can range from “000” to “999”.
(Remote)
►
Remote Mode: RS-232
Baud Rate: 9600
ID: 000
Record Mode
– Sets recording mode between Frame and Field. One frame is equal to two fields.
The default setting is Field.
It is recommended that you leave the Record Mode as Field.
(Menu)
Timer
Record
→
Alarm
Remote
System
Event
(Menu)
Timer
Record
Alarm
→
Remote
System
Event
SYSTEM
Buzzer
– Turns the Buzzer ON/OFF during an Alarm
HDD Overwrite
– Select Yes to have the DVR automatically overwrite
previously recorded video.
(Menu)
Timer
Record
Alarm
Remote
→
System
Event