17
STRATASYS /
THE
3D PRINTING SOLUTIONS
COMPANY
•
What:
calibrate and test the UV radiation from the lamp.
•
Why:
the effectiveness of the UV radiation can change over time.
• Low UV can cause some of the printing material to remain in a liquid state.
•
When:
every 300 hours of printing
•
How:
1. Run the UV Calibration Wizard (Options
wizards
UV Calibration).
2.
Select ‘UV Intensity Calibration’.
3. Expose the UV sensor and check that the glass is clean.
4. The print block passes over the sensor. The wizard
calculates the required UV level.
UV Lamp Calibration
Summary of Contents for Objet24
Page 1: ...Desktop Family 3D Printing System Operator Training Guide Basic Course...
Page 5: ...1 STRATASYS THE 3D PRINTING SOLUTIONS COMPANY Introducing Desktop Family 3D Printers...
Page 7: ...1 STRATASYS MATERIALS OVERVIEW MATERIALS OVERVIEW...
Page 116: ...72 STRATASYS THE 3D PRINTING SOLUTIONS COMPANY APPENDIX...
Page 143: ...1 STRATASYS THE 3DPRINTING SOLUTIONS COMPANY OPERATOR MAINTENANCE PROCEDURES...
Page 151: ...9 STRATASYS THE 3DPRINTING SOLUTIONS COMPANY WEEKLY Pattern Test Wiper Blade Cleaning...
Page 155: ...13 STRATASYS THE 3DPRINTING SOLUTIONS COMPANY MONTHLY Head Alignment...
Page 165: ...23 STRATASYS THE 3DPRINTING SOLUTIONS COMPANY Load Cell Calibration Every 500 Hours...
Page 167: ...25 STRATASYS THE 3DPRINTING SOLUTIONS COMPANY User Maintenance Once a year Every 1000 hours...
Page 186: ...1 STRATASYS THE 3D PRINTING SOLUTIONS COMPANY Support Removal...
Page 190: ...5 STRATASYS THE 3D PRINTING SOLUTIONS COMPANY Design Tips for Easy Support Removal...
Page 196: ...11 STRATASYS FINISHING APPLICATIONS Cleaning SUP705...
Page 198: ...13 Balco WaterJet...
Page 215: ...30 STRATASYS FINISHING APPLICATIONS Cleaning SUP706...
Page 227: ...1 STRATASYS THE 3D PRINTING SOLUTIONS COMPANY Knowledge Resources...
Page 236: ...10 STRATASYS THE 3D PRINTING SOLUTIONS COMPANY THANK YOU...