DT3 CleanStation
DOC-01121 Rev. A
3-16
7.2 Printed Models Take a Long Time to Clean
• Check the cleaning solution with a hydrometer and change the solution, if
necessary. For instructions on using the hydrometer, see DOC-08380,
"Working with Alkaline Cleaning Solution".
• Check that the suction strainer and the manifold jets are clear of material
deposits (see "Maintenance" on page 12).
7.3 Error Messages on the Control Panel
If an error is displayed (such as Err4 or Err5), contact your Stratasys
representative.
7.4 The DT3 CleanStation Stops Mid-Cycle
• Check that the water level is at least 2.54 cm (1 inch) from the top of the tank.
• Check that the suction strainer and the manifold jets are clear of material
deposits (see "Maintenance" on page 12).