5
www.strata.co.nz
ADVANCECUT 65
*Denotes more detailed explanation of function to follow.
Front View
1.
Cutting Current Control Knob
2.
Power Indicator. Lights when input power
connected and machine switched on
3.
Power Error/ Overload Indicator*
4.
Torch System Error Indicator*
5.
Cutting Power Indicator. Lights when cutting
power circuit activated
6.
Air Control Run/ Set Switch *
7.
Earth Lead Connection Socket
8.
Plasma Torch Euro/ Central Connector
9.
CNC Interface Connection Port
Rear View
10.
Air Pressure Regulator Outlet Pressure Gauge
11.
Air Pressure Regulator Knob
12.
Compressed Air Inlet
13.
Air Condensate Filter/ Trap Bowl
14.
Air Filter Condensate Drain Tube
Further Controls Explained
Overload/ Error Indicator (3)
Lights when over voltage, over current or electrical
overheating (due to exceeding duty cycle) is detected
and protection is activated.
When protection is activated, welding output will be
disabled until the safety system senses the overload
has reduced sufficiently and indicator lamp goes out.
May also trigger if machine experiences an internal
power circuit failure.
Torch System Error Indicator (4)
Lights when issue with torch system or air supply
detected and cutting output is disabled as a result.
Flashing light means that torch shield cap is not in-
Know Your Machine
stalled. Continuous light means likely damaged or
missing torch consumables or insufficient air pres-
sure supply to the torch.
Compressed Air Testing/Setting Switch (6)
When positioned as ‘set’ compressed air control
valve is open continuously. This is useful for testing
and setting the air pressure without having to activate
the trigger circuit. ‘Run’ position is normal operation.
DIMENSIONS: WEIGHT:
INPUT POWER
MAX. INPUT GENERATOR
CURRENT
DUTY CYCLE:
CUT
SEVERANCE COMPRESSED STANDARDS:
SUPPLY:
CURRENT: CAPACITY:
OUTPUT:
CAPACITY:
CAPACITY:
AIR REQ.
640 x 240 x 445mm
24kg
400V AC 20A
18A
12.3KVA
20-65A
100% @ 61A Steel 25mm Steel 35mm
110L/min
EN60974-1:2012
50Hz 3 Ph
Alum. 20mm
5bar
4
5
6
7
9
3
2
1
8
11
10
14
13
12