The switches are located at the right hand side of the heater.
The Standby switch must first be turned ‘ON’ to operate the heater
manually or by remote control.
Note: It takes some time for the receiver to respond to the
transmitter. DO NOT PRESS the buttons more than once within
two seconds for correct operation.
To go to the previous settings press the
button.
Pressing the
button on the remote turns off the light & hea
t
settings. To resume press the button until the desired setting
is reached - see
Fig. 8
.
To increase or decrease the brightness of the flames, use the
dimmer button or the
button on the Remote Control. The heat
setting will remain the same.
To turn off the power the Standby Switch must be turned ‘OFF’.
Lamp Replacement
WARNING – ALWAYS DISCONNECT FROM THE POWER
SUPPLY BEFORE REMOVING LAMPS.
Warning -
The lamps reach high temperatures during operation.
For this reason, allow the lamps to cool down after switching off
the appliance.
The front panel will need to be removed in order to change
lamps.
Warning -
Take care handling the front panel as it can be easily
damaged.
a. Remove the two screws which hold the front panel in place
- see
Fig. 9
.
b. While holding the front by its sides with both hands carefully
tilt forwards
- see
Fig. 9
.
c. Then lift
up
and
out
- see
Fig. 9
Place the front panel flat on a protective surface such as a matt
with the glass facing away from the floor.
Remove the (4) screws securing the lamp cover plate - see
Fig. 10
. Lift the cover plate up and out to remove.
Remove the (2) screws securing the hinged cover - see
Fig.
10
. Tilt the hinged cover (see ‘b’ in
Fig. 11
).
Remove the defective lamp by unscrewing it as shown in
Fig.
12
.
Replace with a 60W E14 SES Clear Candle bulb. Take care not
to over-tighten the lamp.
Steps for reassembling the heater
Refit the hinged cover with fixing screws.
Refit lamp cover plate ensuring that the bend to the rear on the
lamp cover plate slots in between the fuel effect retaining bracket
and the rear glass - see ‘x’ in
Fig. 11
.
Refit the front panel ensuring that its base is held in place i.e.
that it slots into the channel on the frame, reversing the steps
as outlined previously.
Thermal Safety Cut-out
For your safety, this appliance has been fitted with thermal cut-
out. In the event that the product overheats, the cut-out switches
the heat off automatically.
To bring the heat back into operation, remove the cause of the
overheating, then unplug or turn off the electrical supply to the
heater for up to 10 minutes.
When the heater has cooled sufficiently, re-connect and switch
on the heater.
Caution: In order to avoid a hazard due to inadvertent resetting
of the thermal cut-out, this appliance must not be supplied
through an external switching device, such as a timer, or
connected to a circuit that is regularly switched on and off by
the utility.
Cleaning
WARNING – ALWAYS DISCONNECT FROM THE POWER
SUPPLY BEFORE CLEANING THE HEATER.
For general cleaning use a soft clean duster – never use
abrasive cleaners. The glass viewing screen should be
cleaned carefully with a soft cloth. DO NOT use proprietary
glass cleaners.
Recycling
For electrical products sold within the
European Community.
At the end of the electrical products useful
life it should not be disposed of with
household waste. Please recycle where
facilities exist. Check with your Local
Authority or retailer for recycling advice in
your country.