Gas - range
Databadge
Lower part of the front frame
Appliance class
Class 1 - freestanding cooker
Electrical supply
220V - 240V ~ 50Hz
Type of gas
Please see data badge for your specified gas type. Can be convert
-
ed from natural gas to LPG. Never attempt to convert an appliance
unless the data badge states you can.
Gas pressure settings
G20 Natural gas @ 20 mbar
G30 Butane @ 28-30mbar
G31 Propane @ 37mbar
Burner Aeration
Fixed
WARNING -
This cooker must be earthed
Burner / Element
Nat Gas / LPG
(kW)
Injector
(Nat gas)
Injector
(LPG)
Butane g/h Propane g/h
Hob - small
1.00
77
50
73
72
Hob - medium
2.00
104
70
145
143
Hob - large
3.00
129
87
218
215
Hob - wok
4.00
152
100
291
286
Total heat input (5 burners)
12
N/A
N/A
N/A
N/A
Total heat input (7 burners)
15
N/A
N/A
N/A
N/A
Electrical supply / load
Electrical
supply
Oven
Appliance Size (cm) / Load kW
90
100
110
240v
Multifunction
3.1
3.1
3.1
Fanned
2.0
2.0
2.0
Fanned (90cm tall oven)
2.5
N/A
N/A
Fanned (90cm deluxe oven)
1.7 / 3.0
N/A
N/A
Dual variable grill
1.7 / 2.7
1.7 / 2.7
1.7 / 2.7
Conventional top
1.4
1.4
1.4
Slow Cook
N/A
0.17
0.17
Oven Lamps / Fans
Lamps (90cm deluxe
Right Hand Oven)
25W each
Lamps
40W each
Cooling fans
10W each
Oven stir fans
30W each
Electrical supply / load
Appliance
Size (cm)
Electrical
supply
Max. load
(kW)
Dual grill
models
90
220 - 240v
7.10 - 8.45
90 (deluxe)
7.55 - 8.98
10/110
6.83 - 8.13
TECHNICAL DATA
Summary of Contents for RICHMOND S900 DF
Page 1: ...USER GUIDE A commitment to Stoves Range DF GTG Part Number 083644901 Date 30 04 18 ...
Page 54: ...Removing Telescopic shelves USING YOUR APPLIANCE ...
Page 69: ...Please keep this handbook for future reference or for anyone else who may use the appliance ...