background image

Before cleaning or maintenance,
switch off the electricity supply.

Replacing a light bulb

1. Switch off the electricity supply.
2. Remove the grease filters from the

hood.

3. Unscrew the bulb from the holder.

Replacement  bulbs  can  be
obtained  from  your  supplier  or
local hardware store.

4. Fit  the  new  bulb,  ensuring  it  is

screwed securely into the holder.

5. Refit the grease filters.

To  avoid  any  fire  risk,  the  following
cleaning instructions must be followed:

Grease filters

The grease filters absorb grease and
dust from cooking fumes, which would
otherwise damage the inside of the hood.  
The  grease  filter  should  be  removed
and  cleaned  regularly  -  with  normal
use, this should be every 2 months.

I m p o r t a n t :

Frequent  washing  is

essential  to  prevent  a  build  up  of
grease  in  the  filters  which  could
become a fire hazard.
1. Remove the filters from the hood.
2. Carefully wash the grease filters in

hot  soapy  water  and  dry  with  a
clean towel.

3. Refit the clean filters.

Outer casing

All external parts of the outer casing
and visor can be safely cleaned with a
clean  cloth  wrung  out  in  hot  soapy
water.

Do  not  use

caustic  pastes,  abrasive

cleaning  powders,  wire  wool  and
hard implements, as they will damage
the surfaces.

Carbon filters

(models installed for

use with the re-circulation method only)

The  carbon  filters  absorb  cooking
odours and need renewing after about
4  months  of  normal  use.   A  replace-
ment  carbon  filter  can  be  obtained
from your supplier.
Saturation of the activated charcoal in
the filter will depend on how often the
hood is used, the type of kitchen and
the regularity of cleaning the grease filter.

The  carbon  filters  cannot  be
washed - renew every 4 months.

1. Remove the grease filters from the

hood.

2. Release  the  old  carbon  filters  by

twisting them in either direction by
a  quarter  turn  (90˚)  until  they
disengage.

3. Fit  the  new  carbon  filters  by

engaging  them  onto  the  pegs  in
the  centre  of  the  fan  grille  and
twisting by a quarter turn until they
are gripped securely.

4. Refit the grease filters.

5

Care & Maintenance

08 27123 01- 1100TRC hood  17/5/05  4:14 pm  Page 7

Summary of Contents for 1100TRC

Page 1: ...1100TRC Chimney Hood User Installation Instructions 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 1 ...

Page 2: ...08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 2 ...

Page 3: ...ation requirements Mounting height 6 Method 1 Re circulation 7 Method 2 Extraction through an outside wall 8 Wall fixing 9 Electrical connection 10 Frame mounting instructions 11 Technical Data 12 Customer Support 13 Please read this handbook carefully and keep it for future reference 1 Contents 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 3 ...

Page 4: ...ntee and Service availability only apply to the UK and Republic of Ireland Installation This appliance has been designed for use as an exhausting air evacuation to the outside or filtering indoor air re cycling hood Note This appliance may be supplied fitted with carbon filter s for use as a re circulating hood If you wish to install the hood for extraction through an outside wall a compatible duc...

Page 5: ...e grease filters motor carbon filters slider control light bulb frame Outlet adaptor inner chimney extension piece outer chimney extension piece wall bracket adjustable Figure 1 Parts Identification 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 5 ...

Page 6: ... control to the on position To switch off return the control to the off position Important safety notes Keep hob rings covered with pans when switched on to avoid damaging the hood The use of an unprotected flame can cause a fire hazard Do not flambé food underneath the hood When frying foods take care to avoid cooking oil flares Wash the grease filters regularly refer to the cleaning section Do n...

Page 7: ...it the clean filters Outer casing All external parts of the outer casing and visor can be safely cleaned with a clean cloth wrung out in hot soapy water Do not use caustic pastes abrasive cleaning powders wire wool and hard implements as they will damage the surfaces Carbon filters models installed for use with the re circulation method only The carbon filters absorb cooking odours and need renewi...

Page 8: ...ich is not of the balanced flue type Mounting height The cooker hood must be fitted at least 650 mm above a gas or electric hob If cooker hob instructions give a different figure to that given above then the higher measurement should be followed To prevent possible hood cut out a clearance of 750 mm is recommended above gas hobs where possible Select method of operation The cooker hood has two pos...

Page 9: ...en selecting the best position for the hood ensure that air flow from the air ducting vents is not obstructed by cupboards shelves etc Do not vent into enclosed cupboard space Assembly 1 Remove the grease filters 2 Fit the carbon filter if supplied may be packed separately by engaging it onto the peg in the centre of the fan grille and twisting in either direction by a quarter turn 90 until it is ...

Page 10: ...ucting kit and connect to the ducting outlet adaptor Horizontal duct runs should be avoided A slope of 5 or more upwards from the hood to the wall outlet will assist the flow of air The ducting pipe and any connecting pieces should be coupled to the preceding piece by pushing into and never over it the upper part must be fitted over the lower part The outlet from the hood must not be ducted into a...

Page 11: ...e fig 3 Securing the telescopic flue Make sure the the power cables are inside the decorative flue to conceal them Make sure there is an exhaust opening prepared Adjust the width of the support bracket fig 3 then fix it into the ceiling using the screws shown in fig 3 A This should be as shown in fig 2 Connect the flange as per fig 4 Then insert the two pieces of the flue In some cases it may be n...

Page 12: ...eed as follows 1 The wire which is coloured blue must be connected to the terminal marked N neutral LOAD or coloured black 2 The wire which is coloured brown must be connected to the terminal marked L live LOAD or coloured red The fused spur socket should be positioned where is is easily accessible so you can switch off the supply to the hood when renewing the light bulb Figure 6 Typical example o...

Page 13: ...ct C to A before fixing A to B Figure 7 2 Side frame assembly Connect the endcap E to the side bar D From inside the hood pass screw F through the specific hole Fit part B onto screw F Screw E onto B From inside the hood pass screw H through the hole and attach part G Screw part G into sidebar D Repeat on other side Re fit the 3 grease filter panels 479 mm 98 mm 1083mm 98 mm 40 mm 99 mm 99 mm A B ...

Page 14: ... filters x 3 metal filters Motor rating 1 x 250 W Extraction Rate External Position 3 440m 3 H Position 2 378m 3 H Position 1 303m 3 H Extraction Rate Internal Position 3 301m 3 H Position 2 259m 3 H Position 1 227m 3 H Noise level External Venting Position 3 56 dBA Position 2 51 dBA Position 1 48 dBA Noise Level Internal Venting Position 3 59 dBA Position 2 56 dBA Position 1 53 dBA Co nforms with...

Page 15: ...queue Calls are answered in strict rotation as our Customer Support Representatives become available Enter appliance numbers here for future reference Please ensure you have the above details Model No and Serial No to hand when calling Customer Support they are essential to booking your call 13 Model No Serial No Customer Support 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 15 0844 815 3740 ...

Page 16: ...STOVES STONEY LANE PRESCOT MERSEYSIDE L35 2XW 08 27123 01 05 2005 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 16 ...

Reviews: