Regulations and standards

Before you start please read instructions
carefully.  All installations, service and
repair  work  must  be  in  accordance
with local standards and regulations.
In the UK the regulations and standards
are as follows:-
1. Building regulations.
2. The current I.E.E. wiring regulations.
3. Electricity at work regulations 1989.
4. Installation and servicing instructions

for this appliance.

Ventilation

Adequate  ventilation,  in  accordance
with the Gas Safety Regulations 1996
(Installation and Use), and the relevant
building regulations must be provided
when  the  hood  extracts  air  from  a
room  with  a  flued  gas  burning
appliance,  which  is  not  of  the
“balanced flue” type.

Mounting height

The cooker hood must be fitted at least
650 mm above a gas or electric hob.
If  cooker  /  hob  instructions  give  a
different  figure  to  that  given  above,
then  the  higher  measurement  should
be followed.
To  prevent  possible  hood  cut-out,  a
clearance of 750 mm is recommended
above gas hobs where possible.

Select method of operation

The  cooker  hood  has  two  possible
methods of operation:

Method 1: 

Re-circulation.

Installation with dual filtration to clean
the air before it is re-circulated into the
room.

Method  2: 

Extraction  through  an

outside wall.

The hood can be installed with a duct
to  extract  cooking  fumes  through  an
outside wall.

Dimensions

Please  note  that  all  dimensions  and
sizes are nominal, some variation is to
be expected.

6

Installation

08 27123 01- 1100TRC hood  17/5/05  4:14 pm  Page 8

Summary of Contents for 1100TRC

Page 1: ...1100TRC Chimney Hood User Installation Instructions 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 1 ...

Page 2: ...08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 2 ...

Page 3: ...ation requirements Mounting height 6 Method 1 Re circulation 7 Method 2 Extraction through an outside wall 8 Wall fixing 9 Electrical connection 10 Frame mounting instructions 11 Technical Data 12 Customer Support 13 Please read this handbook carefully and keep it for future reference 1 Contents 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 3 ...

Page 4: ...ntee and Service availability only apply to the UK and Republic of Ireland Installation This appliance has been designed for use as an exhausting air evacuation to the outside or filtering indoor air re cycling hood Note This appliance may be supplied fitted with carbon filter s for use as a re circulating hood If you wish to install the hood for extraction through an outside wall a compatible duc...

Page 5: ...e grease filters motor carbon filters slider control light bulb frame Outlet adaptor inner chimney extension piece outer chimney extension piece wall bracket adjustable Figure 1 Parts Identification 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 5 ...

Page 6: ... control to the on position To switch off return the control to the off position Important safety notes Keep hob rings covered with pans when switched on to avoid damaging the hood The use of an unprotected flame can cause a fire hazard Do not flambé food underneath the hood When frying foods take care to avoid cooking oil flares Wash the grease filters regularly refer to the cleaning section Do n...

Page 7: ...it the clean filters Outer casing All external parts of the outer casing and visor can be safely cleaned with a clean cloth wrung out in hot soapy water Do not use caustic pastes abrasive cleaning powders wire wool and hard implements as they will damage the surfaces Carbon filters models installed for use with the re circulation method only The carbon filters absorb cooking odours and need renewi...

Page 8: ...ich is not of the balanced flue type Mounting height The cooker hood must be fitted at least 650 mm above a gas or electric hob If cooker hob instructions give a different figure to that given above then the higher measurement should be followed To prevent possible hood cut out a clearance of 750 mm is recommended above gas hobs where possible Select method of operation The cooker hood has two pos...

Page 9: ...en selecting the best position for the hood ensure that air flow from the air ducting vents is not obstructed by cupboards shelves etc Do not vent into enclosed cupboard space Assembly 1 Remove the grease filters 2 Fit the carbon filter if supplied may be packed separately by engaging it onto the peg in the centre of the fan grille and twisting in either direction by a quarter turn 90 until it is ...

Page 10: ...ucting kit and connect to the ducting outlet adaptor Horizontal duct runs should be avoided A slope of 5 or more upwards from the hood to the wall outlet will assist the flow of air The ducting pipe and any connecting pieces should be coupled to the preceding piece by pushing into and never over it the upper part must be fitted over the lower part The outlet from the hood must not be ducted into a...

Page 11: ...e fig 3 Securing the telescopic flue Make sure the the power cables are inside the decorative flue to conceal them Make sure there is an exhaust opening prepared Adjust the width of the support bracket fig 3 then fix it into the ceiling using the screws shown in fig 3 A This should be as shown in fig 2 Connect the flange as per fig 4 Then insert the two pieces of the flue In some cases it may be n...

Page 12: ...eed as follows 1 The wire which is coloured blue must be connected to the terminal marked N neutral LOAD or coloured black 2 The wire which is coloured brown must be connected to the terminal marked L live LOAD or coloured red The fused spur socket should be positioned where is is easily accessible so you can switch off the supply to the hood when renewing the light bulb Figure 6 Typical example o...

Page 13: ...ct C to A before fixing A to B Figure 7 2 Side frame assembly Connect the endcap E to the side bar D From inside the hood pass screw F through the specific hole Fit part B onto screw F Screw E onto B From inside the hood pass screw H through the hole and attach part G Screw part G into sidebar D Repeat on other side Re fit the 3 grease filter panels 479 mm 98 mm 1083mm 98 mm 40 mm 99 mm 99 mm A B ...

Page 14: ... filters x 3 metal filters Motor rating 1 x 250 W Extraction Rate External Position 3 440m 3 H Position 2 378m 3 H Position 1 303m 3 H Extraction Rate Internal Position 3 301m 3 H Position 2 259m 3 H Position 1 227m 3 H Noise level External Venting Position 3 56 dBA Position 2 51 dBA Position 1 48 dBA Noise Level Internal Venting Position 3 59 dBA Position 2 56 dBA Position 1 53 dBA Co nforms with...

Page 15: ...queue Calls are answered in strict rotation as our Customer Support Representatives become available Enter appliance numbers here for future reference Please ensure you have the above details Model No and Serial No to hand when calling Customer Support they are essential to booking your call 13 Model No Serial No Customer Support 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 15 0844 815 3740 ...

Page 16: ...STOVES STONEY LANE PRESCOT MERSEYSIDE L35 2XW 08 27123 01 05 2005 08 27123 01 1100TRC hood 17 5 05 4 14 pm Page 16 ...

Reviews: