LUBRICANT FILL INSTRUCTIONS
TOPPING OFF LUBRICANT:
The Spincat uses synthetic silicone viscous fluid for a lubricant. To top off the
tool with lubricant, follow steps below. If the tool is being rebuilt or the seal
replaced, the lubricant should be poured directly into the body around the shaft
before the inlet nut is installed. To replace the high pressure seal, follow the steps
on the right.
1. Remove the Port Plug Assembly (FT 026).
2. Remove the Inlet Nut.
3. Refill the Body with viscous fluid to 1/4" above the top of the upper Bearing.
4. Hold the Inlet nut at an angle with the Port Plug hole facing up. Thread Body onto Inlet Nut
and tighten to 50 ft-lb.
5. Install Port Plug
FT 026
Port Plug
with O-Ring