KSE 910 Date 0507
9
Sweeping wet refuse
For sweeping wet refuse, it is recommended that the fan shutter be
closed, to prevent clogging and softening of the filter.
This is how to adjust the fan shutter:,
•
with the machine switched off, open the hood and fasten it.
•
To close the fan shutter, rotate the lever –1-to the front position.
•
To open the fan shutter, you must get the lever –1 into the rear
position.
After sweeping
•
Switch off the machine (see page 7."Switching off the sweeper“).
•
Adjust the side brushes and sweeping rollers in the upper
position.
Caution!
If the sweeping rollers are not set to their top position, the
bristles of the side brushes will be put under permanent load
in their off-position and consequently will wear prematurely
when used.
•
Always empty the dustbin once you've finished sweeping.
(See "Dustbin emptying“)
Emptying the dustbin
In order to ensure proper sweeping performance, the dustbin has to
be emptied at regular intervals.
•
Lift the dustbin securing device –1-and pull the dustbin on the
handle –2-from the frame of the machine.
•
Empty the dustbin into a suitable container.
•
Push the dustbin back into the machine.
Do not park the sweeper with a full dustbin.